Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stub-In Tapport
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • +OpenPlant Isometrics Manager for OpenPlant
          • -OpenPlant Isometrics Manager for AutoPLANT
            • Installation/Upgradation Steps of OpenPlant Isometrics Manager for AutoPLANT
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
              • Description for Bolts, Gaskets In Isometric BOM Showing as "NODESC"
              • Element ‘VALVE_HAS_VALVE_OPERATING _DEVICE’ is missing required attribute ‘sourceClass’
              • Error: Mapping of component not found, Class Name: BASE_AT_LUG_W_BOLT
              • Error: Mapping of component not found, Class Name: AT_PVIC_AT_SOCKETWELD
              • Error: The Process cannot Access the File in OpenPlant Isometrics Manager
              • Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stub-In Tapport
              • Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1
              • Error: XCHG0000: Invalid Translation Format: OPIM in OpenPlant Isometrics Manager
              • Error[0]: Unable to locate ADDON (ID=XXX) to DCP
              • Error[0]: Unable to Locate ADDON (4) to DCP when Miscellaneous Attachment on Pipe
              • Error[5]Cell not found in libraries: GATSW_FT
              • Error[5] Unable to Place Symbol: FLNWNF, PGKT, GATFL When Use Custom Seed File (Backing Sheet)
              • ERROR[5]: DWG creation failed while Generating Isometric Output as DWG Format
              • To Avoid Crash for End Types WFL & Butt Weld Connections in Isometrics
              • Isometric successfully, but PCF generation failed Message in OpenPlant Isometrics Manager
              • Unresolved References Files Error on Opening DWG Isometric in AutoCAD
              • Check Internet Connection and Restart the Setup or Provide Proxy Settings
              • References-Unresolved Reference file error while opening DWG format Isometric drawing in AutoCAD
              • The Specified module could not be found (Exception from HRESULT: 0X8007007E)
            • +Open/Save - OpenPlant Isometrics Manager for AutoPLANT
            • +Processing - OpenPlant Isometrics Manager for AutoPLANT
            • +Settings/Attributes - OpenPlant Isometrics Manager for AutoPLANT
            • How to Change Miscellaneous Attachment Annotation Container in CONNECT Edition
            • How to Create Special Stamps using Detail Sketches in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Create Special Stamps using Reports in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Delete Ecxml Files, after certain Period in CONNECT Edition
            • How to Export Bill of Material In CSV Excel Format for AutoPLANT Modeler in CONNECT Edition
            • How to Publish Isometrics in DGN, DWG and PDF Output Formats in CONNECT Edition
            • How to Save Isometrics Output on Network Drive for AutoPLANT in CONNECT Edition
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stub-In Tapport

    Applies To
    Product(s): OpenPlant Isometrics Manager & AutoPlant Modeler
    Version(s): 08.11.09.458 & 08.11.11.135
    Environment: Windows 7 (64 bit)
    Area: Settings/Attributes
    Subarea:
    Original Author: Abhijit Bute, Bentley Product Advantage Group

    Problem Description

    Using AutoPLANT Modeler & OpenPlant Isometrics Manager user is getting error as "Scaler, Symbols or item codes are missing for TAP_CONNECTION" while generating isometrics as shown below.

    Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when branch connected through Stub-In tap port. 

    Steps to Resolve

    1. Open Class Editor and go to File>Open navigate to project path.
    2. Open ‘OpenPlant_3D.01.04.ecschema.xml’ & supplement it with "OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04.ecschema.xml" Schema.
    3. Search TAP_CONNECTION class.
    4. Change the value in “Item Code” from this.COMPONENT_NAME to “TAG”

      Note - Add the string quotes " " around TAG as "TAG".

    5. Save & close schema.
    6. Restart document manager generate isometric to verify result.

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.

    See Also

    Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
    Processing - OpenPlant Isometrics Manager To Discuss content related to Errors, Logs, Messages, Crashes in OpenPlant Isometrics Manager for AutoPLANT. Isometrics generation Errors/ Reading Logs/Message…
    Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • AutoPLANT Modeler
    • Symbol
    • item code
    • Stub-In Tapport
    • Scaler
    • TAP_CONNECTION
    • OpenPlant Isometrics Manager
    • Share
    • History
    • More
    • Cancel
    • Kestutis Mitkus Created by Bentley Colleague Kestutis Mitkus
    • When: Wed, Dec 12 2018 10:54 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Wed, Dec 19 2018 4:37 PM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies