To round off Support co-ordinates after decimal point in OpenPlant Isometrics Manager.
While labeling the support co-ordinates in OpenPlant Isometrics Manager, values displayed with multiple numeric after the decimal point. It has been required to have the control with specific count after decimal.User wanted to display Bend Angle information with one value after decimal, rounding the values appears to be. Using the similar expression under "Specific BOM labels" custom attribute will aid user to achieve the desired settings. Below has been described in case of Pipe Bend class used while modeling and Angle associated with it.