You are currently reviewing an older revision of this page.
OverviewHow to change isometric coordinate without changing AutoPLANT Modeler coordinate.
Background
When generate isometric by default generated isometric will show component coordinate as per AutoPLANT 3D model coordinate. Sometimes user may have project requirement to change isometric coordinate as per their own coordinate system.
Below steps explain How to change isometric coordinate without changing AutoPLANT Modeler coordinate.
Steps to Accomplish
Refer below image for actual location of ACS.
Define grid so that all model should be covered in define grid.
Grid definition = Grid Name, Direction, X, Y, Z, Rotation, Length.
4. Save file and generate isometrics to review the isometric.
Refer below image in AutoPLANT model pipe coordinate showing 0,0,0
Refer below image in isometric showing coordinate 2000, 500, -750
https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40444/settings-attributes---openplant-isometrics-manager-for-autoplant
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!