Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to place Lapped flange one side and fixed flange other side for Lined Pipe
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • +OpenPlant
      • -Bentley AutoPLANT
        • AutoPLANT Product Group Compatibility
        • +AutoPLANT Modeler CONNECT Edition
        • -AutoPLANT Modeler V8i
          • +AutoPLANT Modeler [FAQ]
          • +Component - AutoPLANT Modeler
          • -Customization - AutoPLANT Modeler
            • How to Add Mitered Elbow in Existing Catalog using Specification Generator
            • How to add Spec Criteria in Project Isometrics
            • How to Assign Pipe Insulation Properties for All Insulated Components in Model
            • How to Change Weld Size Graphics in AutoPLANT Modeler
            • How to Make a Custom Isometric Style Available in the Create Iso via OPIM option
            • How to Make Changes in AutoPLANT to Place Mitered Pipe of more then 45 degree angle.
            • How to obtain Valve Location while creating AutoPLANT Report
            • How to place Lapped flange one side and fixed flange other side for Lined Pipe
            • How to Set Folder Structure of the Document Manager as per Project Requirement in AutoPLANT Modeler
            • How to Show insulation for Strainer and Steam Traps
            • How to update Pipeline insulation color with single color
            • How to use Custom Symbols for Lightning in Cable Tray Module.
          • +Database - AutoPLANT Modeler
          • +Errors, Logs, Messages, Crashes - AutoPLANT Modeler
          • +General - AutoPLANT Modeler
          • +Installation - AutoPLANT Modeler
          • Processing - AutoPLANT Modeler
          • +Settings/Attributes - AutoPLANT Modeler
          • +Tools - AutoPLANT Modeler
        • +AutoPLANT Piping
        • +AutoPLANT Equipment
        • +AutoPLANT I&W
        • +AutoPLANT P&ID
        • +AutoPLANT Isometrics
        • +AutoPLANT AutoISOGEN
        • +Bentley Data Manager
        • +Vision/Document Manager
        • +Drawing Flattener
        • +DataSheets
        • +Specification Generator
        • +ProjectWise Integration
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    How to place Lapped flange one side and fixed flange other side for Lined Pipe

    Applies To
    Product(s): AutoPLANT Modeler
    Version(s): 08.11.XX.XXX
    Environment: Windows 7/8.1/10 (64 bit)
    Area: AutoPLANT Piping
    Subarea:  Lined Pipe
    Original Author: Abhijeet Shinde, Bentley Product Advantage Group

    Background

    Some project may have requirement in Lined Pipe Module to show fixed flange on one side (FLL) and Lapped joint flange on another side (LPL) of Pipe.

    This article explains how to place Lapped flange one side and fixed flange other side for Lined Pipe.

    Steps to Accomplish

    1. Define End Condition 2 ‘FLL’ in desired spec. Refer following screenshot where modified out of box Metric spec Mrsf, and added the End Condition 2 “FLL”.



    2. Modify ‘PORTS.INI’ file.
      Note: PORTS.INI file can be modified on project level if user want to apply settings on project level.

      Following setting will be applicable for all projects.
      1. Go to following path,C:\Program Files (x86) \Bentley\Modules\LinePipe



      2. Open PORTS.INI file in notepad. And search for ‘PipePorts’.
        Modify Port2.EC = END_COND_2



      3. Save file.

    3. Open AutoPLANT Modeler place Line pipe using Mrsf spec and review End condition.

    See Also

    Customization - AutoPLANT Modeler
    All customization related issues will be discussed in this section.
    Last edited over 5 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • LinedPipe
    • AutoPLANT Modeler
    • Line pipe Module
    • AutoPlant V8i
    • AutoPLANT Piping
    • Share
    • History
    • More
    • Cancel
    • Abhijeet Shinde Created by Bentley Colleague Abhijeet Shinde
    • When: Fri, May 3 2019 7:35 AM
    • Abhijeet Shinde Last revision by Bentley Colleague Abhijeet Shinde
    • When: Tue, May 7 2019 1:31 AM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies