You are currently reviewing an older revision of this page.
Some project may have requirement in Lined Pipe Module to show fixed flange on one side (FLL) and Lapped joint flange on another side (LPL) of Pipe.
This article explains how to place Lapped flange one side and fixed flange other side for Lined Pipe.
Steps to Accomplish
1. Define End Condition 2 ‘FLL’ in desired spec.Refer following screenshot where modified out of box Metric spec Mrsf, and added the End Condition 2 “FLL”
2.Modify ‘PORTS.INI’ file.
Note: PORTS.INI file can be modified on project level if user want to apply settings on project level.
Following setting will be applicable for all projects.
Modify Port2.EC = END_COND_2
3.Open AutoPLANT Modeler place Line pipe using Mrsf spec and review End condition.
https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/35584/customization-autoplant-modeler
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!