Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPLANT | OpenPlant | PlantWise
  • Product Communities
  • More
AutoPLANT | OpenPlant | PlantWise
AutoPLANT | OpenPlant | PlantWise Wiki Configuration Variables - BRCM
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • +OpenPlant
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • -Bentley Raceway and Cable Management
        • Bentley Raceway and Cable Management Product Compatibility
        • -CONNECT Edition - Bentley Raceway and Cable Management
          • +Resolved issues in Bentley Raceway and Cable Management Releases
          • +AutoPlace Conduit tool - BRCM CONNECT Edition
          • +Cable Reports- Cable Pull Cards and Cable Drums-Bentley Raceway and Cable Management CONNECT Edition
          • +Cable Routing-Bentley Raceway and Cable Management CONNECT Edition.
          • +Drawing generation - Bentley Raceway and Cable Management CONNECT Edition
          • How to clear the imported cable or equipment data from Database in the Bentley Raceway and Cable Management CONNECT Edition
          • How to Import Cable List into BRCM CONNECT
          • +i-Model - Bentley Raceway and Cable Management CONNECT Edition
          • -Installation_Configuration - BRCM CONNECT
            • Configuration Files - BRCM
            • Configuration Variables - BRCM
            • Database Replication for Bentley Raceway & Cable Management
            • How to configure Bentley Raceway and Cable Management CONNECT Edition with SQL database using Windows Authentication.
            • How to configure BRCM database connection string without the requirement of ODBC DSN.
            • How To create Deployment Image for BRCM CONNECT
            • How to Deploy a Shared WorkSpace in BRCM CONNECT Edition
            • How to do Silent installation of Bentley Raceway and Cable Management CONNECT Edition
            • How to install BRCM CONNECT Edition
            • How to Install BRCM CONNECT in a custom location
            • SQL Server IO Latency - BRCM
            • To assign Minimum SQL User Permissions for Bentley Raceway and Cable Management.
          • +Power Platform Support - BRCM CONNECT Edition
          • +Project Setup- Bentley Raceway and Cable Management
          • +ProjectWise Integration - Bentley Raceway and Cable Management CONNECT
          • +Raceway Design Tools - Bentley Raceway & Cable Management
          • +Raceway IDs - Bentley Raceway and Cable Management CONNECT
          • +Reports - Output Manager - BRCM CONNECT Edition
          • To View the Contents of DGN File in BRCM Explorer after Referencing a DGN from OpenPlant Modeler
          • +Underground System - Bentley Raceway and Cable Management CONNECT Edition
          • +User Defined Attributes (UDA) Settings - Bentley Raceway and Cable Management CONNECT Edition
          • +Components Center - Bentley Raceway and Cable Management CONNECT Edition
          • How to Configure new Columns for Cable Types in Options
          • +i-Twin Services-Bentley Raceway and Cable Management CONNECT Edition.
        • How to Download Bentley Raceway and Cable Management
        • +V8i - Bentley Raceway and Cable Management
        • +What's New in Bentley Raceway and Cable Management Releases
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    Configuration Variables - BRCM

    Product(s): Bentley Raceway and Cable Management CONNECT Edition
    Version(s): CONNECT Edition
    Environment: N/A
    Area: Installation_Configuration
    Subarea: N/A

    Overview

    In the CONNECT Edition, the software utilizes the native Power Platform configuration system to locate the dataset, connect to the project database, and specify various default settings.

    Note: Power Platform is the MicroStation core application that underlies the CONNECT Edition product.

    New configuration variables have been introduced that can be set in any configuration file to configure the software. The purpose of this article is to provide a comprehensive list of the application specific variables that are used to configure the software and explain their purpose.

    BRCM Configuration Variables

    Application variables are prefixed with “BRCM_” to set them apart from the standard Power Platform variables.

    The following table provides a complete list of the application specific variables and explains their purpose:

    Name

    Operator

    Value Type

    Value (typical)

    Description

    BRCM_APPLICATION

    =

    String

    BRCM

    Short name of the application

    BRCM_DB_CONNECTSTRING 

    =

    String

    DSN=BRCMUSER;UID=BRCMUser;PWD=BRCM

    Connection String for SQL Server Database.

    BRCM_DB_ID 

    =

    String

     MYWORKSET

    Prefix given to the SQL table names which typically matches the WorkSet name.

    BRCM_DB_STATIONID   

    =

    String

    $(computername)

    Unique work station ID.

    BRCM_DIR

     

     

    C:\Program Files\Bentley\Bentley Raceway and Cable Management CONNECT Edition\BRCM\

     

    BRCM_FILE_UPDATE_OPTION

     

     

    1

    Controls how data is saved to the database when the design file is closed (0: no update, 1: Prompt to update, 2: silent update)

    BRCM_IMODEL_PUBLISH_MODE

     

     

    0

    Not used in CONNECT Edition

    BRCM_WS_EQUIPMENT

    =

    String

    C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\equipment

    Location of equipment data files

    BRCM_WS_LANGUAGE

    =

    String

    EN

    Language Code for localized metadata files

    BRCM_WS_METADATA

    =

    String

    C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\metadata

    Location of metadata files.

    BRCM_WS_RACEWAY

    =

    String

    C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\raceway

    Location of raceway data files.

    BRCM_WS_RACEWAY_TEMPLATES

    =

    String

    C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\raceway\Templates

    Location of raceway templates.

    BRCM_WS_SCHEMAS

    =

    String

    C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Standards\BRCM\std_dataset\schemas

    Location of EC schema files.

    BRCM_PW_SUBFOLDER_CPC

    =

    String

    \Cable Pull Cards   

    Project subfolder for cable pull cards

    BRCM_PW_SUBFOLDER_REPORTS

    =

    String

    \Reports

    Project subfolder for reports

    BRCM_IMAGE_PATH

    =

    String

    C:\ProgramData\Bentley\BRCM CONNECT Edition\Configuration\Workspaces\BRCM Metric Example\Worksets\BRCM_EU_EN\Standards\BRCM\Reports\Images

    Location of the cable routing path images.

    BRCM_OPM_CABLE_CONNECTION

    =

    String

    ELECTRICAL_DEVICE_OFFSET

    X,Y,Z Offset from the insertion point of the OPM equipment for electrical device.

    These configuration variables can be set in any configuration file. To understand how these variables are used in the configuration files that are delivered with a default installation of the software, please refer to the Configuration Files article.

    • CONNECT Edition
    • administration
    • en
    • bentley raceway and cable management
    • Installation_Configuration
    • Share
    • History
    • More
    • Cancel
    • Scott Walker Created by Bentley Colleague Scott Walker
    • When: Mon, Nov 18 2019 3:08 PM
    • Lalitesh Vaidyar Last revision by Bentley Colleague Lalitesh Vaidyar
    • When: Thu, Sep 3 2020 12:51 PM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies