To Fix Incorrect Weight Calculation of Pipes in Mix Metric Workset.
In Mix Metric WorkSet of OpenPlant Modeler the Total Weight at times is incorrectly calculated. This could be because the specification record contains the weight in kg/m and the length is measured in mm.The total weight is calculated as:
Weight (per length) x Length (in mm)This causes the weight to be multiplied by 1000 times which is incorrect.This wiki mentions procedure to resolve this concern.
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/13393.settingsattributes-openplant-isometrics-manager
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!