User may face problem while generating isometric, generated isometric will not read the override.txt file changes.
Background
Older version of AutoPLANT IsoProj.cfg not included the path for Override, hook up files. In AutoPLANT Modeler CONNECT Edition version those paths required to read the Override.txt and Hook.ini file.
This Wiki article explains the steps helps to modify Older version V8i IsoProj.cfg file to work on AutoPLANT Modeler CONNECT Edition.
1. Navigate to the Project location
For ex: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\Isometrics
2. The older Overrides.txt not working because the following variable is missing in older IsoProj.cfg file.
# Overrides file
IE_OVERRIDES = $(IE_CONF)overrides.txt
# Iosmetric pre/post processing configuration
IE_HOOK = $(IE_CONF)hook.ini
# Configuration file for ProjectWise title block integration
IE_CFG_PROJECTWISE = $(IE_CONF)projectwisemap.txt
3.Save the file and review the results.
4.After doing above changes overrides.txt functionality works fine
AutoPLANT - OpenPlant Isometrics Manager CONNECT Edition OpenPlant Isometrics Manager CONNECT - AutoPLANT See Also AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to… Last edited over 4 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!