In AutoPLANT Modeler CONNECT Edition Update 1, when user tried to changed the Line Number in the “Component Preferences” box for Sample Metric & Mixed Metric Project. User may face below Error message.
This issue is caused due to the wrong Projdata defined in Sample Metric & Mixed Metric projects and it contains following data
As you can see these PSPEC_NOM and PSZ_NOM columns correspond to Imperial units and it should be corrected for Metric and Mixed Metric Project.
Steps to resolve
1.For Metric Project: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i\Projects\SAMPLE_MMETRIC\Projdata\Projdata.mdb (Table PROCESS):
PSPEC_NOM field should contain the name of Metric Specification. Just add 'M' character, so 'CS150' becomes 'MCS150'.
PSZ_NOM field should contain nominal size value. It can be any variant of existing sizes. For e.g 100mm.
2.For Mixed Metric Project: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i\Projects\SAMPLE_MMETRIC\Projdata\Projdata.mdb (Table PROCESS):
PSPEC_NOM field should contain the name of Mixed Metric Specification. Just add 'MM' character, so 'CS150' become 'MMCS150'.
PSZ_NOM field should contain nominal size value. It can be any variant of existing sizes. For e.g 100mm
AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to-use 3D plant design and modeling software The applications included in AutoPLANT Modeler CONNECT Edition suite are AutoCAD-based… Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!