In AutoPLANT Modeler while tried to open the Document Manager, Project Administrator and other utilities the CONNECT Project dialog pop ups to register the AutoPLANT Project on Bentley Cloud Services.
Similar Dialog Pop ups when Open OpenPlant Isometrics Manager from Out session (from Desktop Icon or from Start menu)
In AutoPLANT Modeler, when user opens the Document Manager, Project Administrator and other utilities the CONNECT Project Dialog open ups to register the AutoPLANT Project on Bentley Cloud Services.
Sometimes user do not wants to associate or register their AutoPLANT Project with Bentley Cloud Services.
Following illustrative steps will helps to disable the CONNECT Project Dialog Box.
1.Go to following path
C:\ProgramData\Bentley\Plant V8i\CFG
2.Open the at.ini file
3.Search for CONNECT_DIALOG Variable and change the value from 1 to 0
AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to-use 3D plant design and modeling software The applications included in AutoPLANT Modeler CONNECT Edition suite are AutoCAD-based… Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!