Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki OPIM Isometric Output for DWG file Shows Line Weight Thick as Compared to DGN file
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • +OpenPlant
      • -Bentley AutoPLANT
        • AutoPLANT Product Group Compatibility
        • -AutoPLANT Modeler CONNECT Edition
          • "Error occured during execution. Please refer to ErrLog.txt for details" appears when building a catalog in Spec Gen.
          • -AutoPLANT - OpenPlant Isometrics Manager CONNECT Edition
            • Cannot Extract Isometric Drawing with Particular Drawing file within the Same Project in OpenPlant Isometric Manager CONNECT Edition.
            • Error Symbol not Mapped in [PCF] section: FLOW_ARROW Error Appears when Tried to Generate the Isometric Drawing in OpenPlant Isometric Manager CONNECT Edition
            • How to Add Coordinate Information with the Comment in the Isometric Drawing Using OPIM
            • How to add Spec Criteria in Project Isometrics in AutoPLANT Modeler CONNECT Edition
            • How to Add Spec information for Equipment Nozzle in Isometric Continuation
            • How To Create Custom Style in AutoPLANT Modeler and OpenPlant Isometrics Manager CONNECT Edition .
            • How to Fix the Scaling of PARTID Labels of Welds in OpenPlant Isometrics Manager
            • How to Generate Spool Isometrics in OpenPlant Isometrics Manager
            • How to Generate the PCF File in AutoPLANT Modeler CONNECT Edition
            • How to Hide Specific Character from String by using Hook.ini
            • How to Include Dummy Leg Support under Support Section of Bill of Material in OpenPlant Isometric Manager
            • How to Publish Isometrics in DGN, DWG and PDF Output Formats in OpenPlant Isometric Manager CONNECT Edition
            • How to Remove Flow Arrow Annotation in OpenPlant Isometrics Manager CE
            • How to Resolve “Invalid Seed file” Error message Appears in the Message Center after generating Isometric Drawing.
            • How to Setup the distance of Components from Dimension Extension or witness line, for Different End Conditions
            • How to show Inch-Día Report in OpenPlant Isometrics Manager
            • How to use the Isometric Symbol of Adjustable Support for Single and Double Trunnion Support in OpenPlant Isometric Manager
            • OPIM gets crash when tried to generate the isometric drawing from OPIM Out session
            • OPIM Isometric Output for DWG file Shows Line Weight Thick as Compared to DGN file
            • Overrides.txt is not working when upgrade older AutoPLANT SS5 Project in AutoPLANT Modeler CONNECT Edition
            • The type Initializer for Bentley Isometrics Common Common Utils Thew an Exception Error Appears When Tried to Generate Isometric in OpenPlant Isometric Manager CONNECT Edition
            • Unable to Generate the Isometric Drawing while working with AutoPLANT and OpenPlant Isometrics Manager CONNECT Edition
            • XCHG0401:Unable to Process Component Error Pops up while Generating the Isometric Drawing in AP_OPIM
          • AutoPLANT IModelBridge Workflow
          • +AutoPLANT Modeler CONNECT Edition [FAQ]
          • Bentley Class Editor shows Empty Class List while working with VMware in AutoPLANT Modeler
          • +Customization - AutoPLANT Modeler CONNECT Edition
          • +Database - AutoPLANT Modeler CONNECT Edition
          • Error ‘’Could not Find Acceptable License, Application will Run in Limited Mode’’ Appears when tried to Open the I Model Connector in a Separate Machine.
          • +Errors, Logs, Messages, Crashes - AutoPLANT Modeler CONNECT Edition
          • +General - AutoPLANT Modeler CONNECT Edition
          • How to Push Data to ImodelHub using AutoPLANT IModelBridge
          • +Installation - AutoPLANT Modeler CONNECT Edition
          • Processing - AutoPLANT Modeler CONNECT Edition
          • +Settings/Attributes - AutoPLANT Modeler CONNECT Edition
          • +Tools - AutoPLANT Modeler CONNECT Edition
        • +AutoPLANT Modeler V8i
        • +AutoPLANT Piping
        • +AutoPLANT Equipment
        • +AutoPLANT I&W
        • +AutoPLANT P&ID
        • +AutoPLANT Isometrics
        • +AutoPLANT AutoISOGEN
        • +Bentley Data Manager
        • +Vision/Document Manager
        • +Drawing Flattener
        • +DataSheets
        • +Specification Generator
        • +ProjectWise Integration
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    OPIM Isometric Output for DWG file Shows Line Weight Thick as Compared to DGN file

    Applies To
    Product(s): AP_OPIM  CONNECT Edition
    Version(s): 10.00.XX.XX
    Environment: Windows 7/8.1/10 (64 bit)
    Area: Settings\Attributes
    Subarea: 
    Original Author: Abhijeet Shinde, Bentley Product Advantage Group

    Overview

    While working with AP_OPIM when tried to generate isometric drawing, user gets thick Line Weight in Isometric drawing in DWG format which is not ideal output.

    Background

    In AP_OPIM CONNECT while creating isometric drawing, user gets thick Line weight in isometric drawing  for DWG format but Line Weight for DGN format shows correctly. There might be some issue with DGN to

    DWG conversion settings and this setting are saved in opim.dws file which is located under each style folder.  

    This wiki article explains the steps to resolve this issue.

    Steps to Accomplish

    1.Open Project Administrator

    2.Open the isometric configuration for particular working project.

    3.Open Seed file

    4.After opening Seed file, go to File and click on Save As option

    5.Select Save As type as Autodesk DWG files and click on Options tab

    6.Expand Line Weights section

    7.Set the DWG Weight in between 0.07-0.09 MM and save the DWG Settings file.

    Isometric Output:

    See Also

    AutoPLANT - OpenPlant Isometrics Manager CONNECT Edition
    OpenPlant Isometrics Manager CONNECT - AutoPLANT See Also AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to…
    Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Still a Problem?

    If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • Thick
    • AutoPLANT Modeler
    • AP-OPIM
    • Line Weight
    • OpenPlant Isometrics Manager
    • DWG Format
    • Share
    • History
    • More
    • Cancel
    • Abhijeet Shinde Created by Bentley Colleague Abhijeet Shinde
    • When: Thu, Sep 17 2020 9:58 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies