In OpenPlant Modeler CONNECT Edition, To set different Inlet/outlet ratings for Relief Valves in OpenPlant Modeler.
In OpenPlant Modeler, requirement is to show the inlet/outlet rating in properties & set the system to achieve the joint as per different rating in relief valve. Let’s understand this by the example, requirement is to achieve the relief valve with following conditions : Inlet rating > 150 LB Outlet rating > 300 LB Inlet diameter > 100 mm Outlet diameter > 150 mm By default, the application only shows the inlet rating as shown
This wiki article explains the same how to achieve the results as follows.