        • -AutoPLANT Modeler CONNECT Edition
          • "Error occured during execution. Please refer to ErrLog.txt for details" appears when building a catalog in Spec Gen.
          • +AutoPLANT - OpenPlant Isometrics Manager CONNECT Edition
          • AutoPLANT IModelBridge Workflow
          • +AutoPLANT Modeler CONNECT Edition [FAQ]
          • Bentley Class Editor shows Empty Class List while working with VMware in AutoPLANT Modeler
          • +Customization - AutoPLANT Modeler CONNECT Edition
          • +Database - AutoPLANT Modeler CONNECT Edition
          • Error ‘’Could not Find Acceptable License, Application will Run in Limited Mode’’ Appears when tried to Open the I Model Connector in a Separate Machine.
          • +Errors, Logs, Messages, Crashes - AutoPLANT Modeler CONNECT Edition
          • +General - AutoPLANT Modeler CONNECT Edition
          • How to Push Data to ImodelHub using AutoPLANT IModelBridge
          • -Installation - AutoPLANT Modeler CONNECT Edition
            • AutoPLANT Modeler CONNECT Edition - Installation Procedure
            • AutoPLANT Modeler CONNECT Edition - Uninstallation Procedure
            • AutoPLANT Modeler CONNECT Edition Update 1 Installation Procedure
            • AutoPLANT Modeler CONNECT Edition Update 1-Silent Installation Procedure
            • -AutoPLANT Modeler CONNECT Edition Update 2 Installation Procedure
              • “Bentley AutoPLANT Modeler CONNECT Edition 2 Setup Wizard Failed” message appears when tried to uninstall AutoPLANT Modeler
            • AutoPLANT Modeler CONNECT Edition Update 2- Silent Installation Procedure
            • AutoPLANT Modeler CONNECT package included Applications
          • Processing - AutoPLANT Modeler CONNECT Edition
          • +Settings/Attributes - AutoPLANT Modeler CONNECT Edition
          • +Tools - AutoPLANT Modeler CONNECT Edition
        • +AutoPLANT Modeler V8i
        • +AutoPLANT Piping
        • +AutoPLANT Equipment
        • +AutoPLANT I&W
        • +AutoPLANT P&ID
        • +AutoPLANT Isometrics
        • +AutoPLANT AutoISOGEN
        • +Bentley Data Manager
        • +Vision/Document Manager
        • +Drawing Flattener
        • +DataSheets
        • +Specification Generator
        • +ProjectWise Integration
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    AutoPLANT Modeler CONNECT Edition Update 2 Installation Procedure

    Applies To
    Product(s): AutoPLANT Modeler CONNECT Edition Update 2
    Version(s): 10.02.XX.XX
    Environment: Windows 8.1/10 (64 bit)
    Area: Installation
    Subarea: 
    Original Author: Abhijeet Shinde, Bentley Product Advantage Group

    Overview

    The AutoPLANT Modeler CONNECT Edition Update 2 suite installation procedure is given below.

    General Information

    This build supports-

    • Windows 8.1 (64bit) and windows 10 (64bit)

    • Office 2013, 2016 and office 365/2013 and 365/2016 (both 32bit and 64bit)

    • SQL server 2017/2019 (Enterprise /Standard /Express Edition)

    • ORACLE 11g Release 2 (v11.2.0.3) /12c Release 2 (v12.2.0.1.0).

    • Run windows update to ensure that the latest version of .NET Framework is installed.

    • The Run time version of Microsoft access is not supported
    • The professional version of Office (including Microsoft Access) is required
    • To Enable use of Bentley Project Administrator
    • For the generation of reports via data manager, vision and document manager etc

    Note: AutoPLANT will not get installed on machines having Access Database Engine 2016 64 bit. User will have to uninstall Access database engine and then install AutoPLANT. Access Database Engine 2016 (64 bit) can be installed after installing AutoPLANT on Office 2016 (or 365) x64

    Installation Sequence 

    1.Running Microsoft Access before installing AutoPLANT Applications

    Before installing any AutoPLANT Product, Microsoft Access must be run once to register user’s credentials such as name and initials

    Failure to do this will result in an error message when previewing reports via applications such as Data Manager, Vision, Spec gen 2D/3D Consistency Reporter etc. failure to do so will also result in an empty Microsoft access window being displayed

    2.Running AutoCAD before Installing and running AutoPLANT Applications.

    Before starting the Prerequisites and Common Tools for AutoPLANT Applications installation, AutoCAD must be run once whilst logged in with the administrator account that is performing the installation.

    Once the installation is complete, AutoCAD must be run once more for all other user account such as standard user, before running any AutoPLANT application. This process ensures that AutoPLANT will be registered with the specific AutoCAD version that the user is running.

    Once AutoPLANT is installed, we recommend the use of AutoPLANT products through a Standard user account instead of an Administrator account.

    3.Install AutoPLANT Modeler CONNECT Edition Update 2(10.02.00.48). We will go through the following dialog.

    (Note: For Installation AutoPLANT Modeler CONNECT Edition Update 2 requires to run one installation setup)

    4.Modeler and  iModel Bridge options should be check on for the installation of AutoPLANT Modeler and iModel Bridge.

    5.Check in the check box to select the Unit type as per requirement of Project. Select the require AutoCAD version as per your requirement.

    6.If user wishes to use AutoPLANT Isometrics then check on the indicated option as shown in below screenshot.

    7.Restarting after AutoPLANT Installation

    It is mandatory to restart the machine after installation.

    AutoPLANT Applications will not work properly if the machine is not restarted after the installations.

    See Also

    AutoPLANT Modeler CONNECT Edition
    Work remotely or connected with the market’s most productive and easy-to-use 3D plant design and modeling software The applications included in AutoPLANT Modeler CONNECT Edition suite are AutoCAD-based…
    Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Still a Problem?

    If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • CONNECT Edition
    • AutoPLANT Modeler CONNECT Edition Update 2
    • Installation sequence
    • Installation Procedure
    • Share
    • History
    • More
    • Cancel
    • Abhijeet Shinde Created by Bentley Colleague Abhijeet Shinde
    • When: Tue, Sep 29 2020 7:46 AM
    • Abhijeet Shinde Last revision by Bentley Colleague Abhijeet Shinde
    • When: Tue, Oct 6 2020 11:25 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies