How To Display Level Name and Symbology For HVAC Components in OpenPlant Modeler CONNECT EDITION



Applies To 
Product(s):OpenPlant Modeler CONNECT Edition
Version(s):

 CONNECT Edition

Environment: Windows 10 (64-bit)
Area: Customization
Subarea: HVAC
Original Author:Harshavardhan K, Bentley Product Advantage Group

Background

In OpenPlant Connect Edition, We generally do not have default expression for HVAC components. Let’s create an Expression to define Symbology and level. In this wiki article we  shall try to achieve the same for HVAC components.

Steps to Accomplish

  1. Launch a Blank dgn in OpenPlant Modeler, navigate to OPModeler.dgnlib by clicking on File > Browse and navigate to C:\ProgramData\Bentley\OpenPlant CONNECT Edition\Configuration\Workspaces\WorkSpace\WorkSets\DEMOPS\Standards\OpenPlant\Modeler\Dgnlibs and open the file to edit for customization.



  2. Create a New level using Level manager and assign a temporary level name, Click on Level manager and Create new level called as TEMP and assign a color to it.



  3. From the top left corner change the workflow to Admin and open the element templates from the attributes ribbon.





  4. In Element Templates window, expand OPModeler.dgnlib and create a New Template Group as HVAC and right click on Group to create New Template as Model, Centerline and Insulation.





  5. Once templates are created, click on Utilities and select update templates from libraries.



  6. Change the workflow to OpenPlant Modeler and in Utilities tab, select Named Expression to add expression for HVAC components.



  7. Create click on + icon to create new expression for Model, Centerline and Insulation. Check Images below.







  8. Now close the Named Expression window and click on the green arrow at the left bottom corner to go back to our active dgn from OPModeler.dgnlib file.



  9. Verify Results as below in Dgn file.





See Also

communities.bentley.com/.../how-to-use-break-command-in-openplant-modeler

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround