10.08.00.51
In OpenPlant Isometrics Manager, mid-point dimensioning for pipe coupling in generated isometric output.
OpenPlant Isometrics Manager CONNECT Edition doesn’t show mid-point dimension by default for inline fitting components. Also, enabling dimension feature doesn’t impact dimension for mid-point in case of fitting element like pipe coupling, refer image below. To enable mid-point dimension, we will create rule to achieve the desired output.
RULEINCLUDE=IE_TYPE=CT_FITTING.*Midpoint = 1
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.