In the AutoPLANT Modeler, sometimes user may face below error message when user tried to open the Spec in Specification Generator
The reason behind this file corruption are as follows.
1. Database files grow with the usage
When user add, update data or make any changes in its Access Database design then it raises the size of the Access Database.
2.Database files become corrupted
When the file is shared over a network and multiple users work directly with the file so there are small chances of file corruption.
This wiki article explains the steps to help resolve this issue.
Follow below Steps with your Spec and Catalog.
1.Open the Spec in Microsoft Access.
2. Go to Database Tools and select Compact and Repair Database option
3. Save Spec.
4. Follow same steps with Catalog.
AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to-use 3D plant design and modeling software The applications included in AutoPLANT Modeler CONNECT Edition suite are AutoCAD-based… Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki