Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki To exclude Existing fittings' Part-IDs or to reset Part-IDs
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • -OpenPlant Isometrics Manager CONNECT
          • [FAQ] - OpenPlant Isometrics Manager CONNECT Edition
          • Release Notes- OpenPlant Isometrics Manager CONNECT Edition
          • -OpenPlant Isometrics Manager CONNECT - OpenPlant
            • +Errors, Logs, Messages, Crashes in CONNECT - OpenPlant Isometrics Manager
            • How the part ID labels is grouped under single group in OpenPlant Isometrics Manager.
            • How To Add Detail Sketches in OpenPlant Isometrics Manager CONNECT Edition.
            • How to Allow/Disallow Isometric to Post to PW when Iso-genertion fails.
            • How to Assign the Alphabetic order to Spools instead of Number.
            • How to Cascade ISO Sheet Number to Spool ID User Label CONNECT EDITION
            • How to Change the Color of Leader Line in Isometric via OpenPlant Isometric Manager.
            • How to change the Format of Revisions for Isometrics.
            • How to Combine the BOM in Isometric with Certain Sequence.
            • How to configure Dummy Leg Support in OPIM
            • How To Create a Custom Symbols in OpenPlant Isometric Manager.
            • How to Depict Offsets in OpenPlant Isometrics Manager.
            • How to Disable the Terminator on Leader Line in Isometrics via OpenPlant Isometric Manager.
            • How to Display Dual Dimension inside Isometrics Drawing in CONNECT Edition.
            • How to Enable Mid-Point Dimensioning for Pipe Coupling in OpenPlant Isometrics Manager CONNECT Edition
            • How to Enable the Specific Component Tags to be shown in Isometrics Drawing Using User Label
            • How to Generate Continuous Welds Throughout the Isosheet
            • How to generate correct isometric of pipeline if the component state is different.
            • How to get Model Name in Isometric Output for OPIM CE
            • How to Get Tag Number on Olets in OpenPlant Isometrics Manager
            • How to Get Tag Number on Pipe in OpenPlant Isometrics Manager
            • How to Get Tag Number on Valves in OpenPlant Isometrics Manager
            • How to Hide Component Dimension in OpenPlant Isometrics Manager.
            • How to Increase/Decrease the Length & Gap Between Leader Line & Component in Isometric via OpenPlant Isometric Manager.
            • How to Insert a Detailed Sketch along with a Note Text in Isometrics.
            • How to Manage Gasket Tick Appearance in Dimension for OpenPlant Isometrics Manager CE
            • How to Modify various Hatching properties in OpenPlant Isometrics Manager.
            • How To Move The Loose Fittings To The Shop Material in Bill Of Material via OpenPlant Isometrics Manager.
            • How to select custom WorkSpace/WorkSet at Network Location While Launching OpenPlant Isometrics Manager
            • How to Separate the Pipe & Flange Dimension is Isometric.
            • How To Set an Argument to Launch OpenPlant Isometrics Manager from Network Drive Configuration.
            • How to set different Output Format for Isometrics.
            • How to set Precision Coordinates for Components in PCF file.
            • How to set Precision for Pipe Bend in Isometric Output of OPIM CE
            • How to set Precision for Trimmed Elbows in Isometric Output of OPIM CE
            • How to set Supports at Last in Sequence in BOM of Isometric.
            • How to Set the Border For Isometric in a PDF Output
            • How To Show Continuation with Reference File in OpenPlant Isometrics Manager
            • How to Show Trim Angle Details for Elbow in OpenPlant Isometrics Manager CONNECT Edition
            • How to use PIPEFL symbol for flanged pipes in OpenPlant Isometrics Manager
            • Logic for Shop and Field welds in OPIM CE
            • OpenPlant Isometrics Settings for AutoPLANT Modeler for Project Isometrics
            • To exclude Existing fittings' Part-IDs or to reset Part-IDs
            • To Exclude labels having Null Values in OPIM CE
            • To Resolve Max. Hatch Line Setting not getting Saved in OPIM
          • +OpenPlant Isometrics Manager CONNECT - AutoPLANT
          • How the North for isometrics can be change in OpenPlant Isometrics Manager CONNECT Edition.
          • How to add End type Information in Isometric BOM Cut list OPIM CE
          • How To Add Field components Under Shop Material In BOM OPIM CE
          • How to Add Plant Area in Isosheet Name.
          • How to change Dimension color in OPIM CE
          • How to convert units of Dimension & Size in Isometrics.
          • How To Create Custom Style in OpenPlant Isometrics Manager Connect Edition .
          • How to Create new Drawing Attribute Combining Multiple other Drawing Attributes and Map with New Text Node in OpenPlant Isometrics Manager
          • How to customization ISO sheet number (split sheet number / Total number of sheet) In OpenPlant Isometrics Manager
          • How to disable Dimension for Existing Component State
          • How To Display only Support List for Bill Of Material Report in OpenPlant Isometrics Manager
          • How to Generate Reports based on Size in OpenPlant Isometrics Manager Connect
          • How to get Co-ordinate Values in Meters in Iso Output via OPIM
          • How to Get Updated Revision in Isometrics Drawing Using DBQuery in OpenPlant Isometric Manager CONNECT Edition
          • How to Hide Branch Dimensions
          • How to modify/edit Dimension Text of extracted DWG from OPIM CE
          • How to place Text Node in OPIM CE
          • How to Remove Insulation/Tracing for desired components in Isometrics.
          • How To Resolve the error message " OPIM_SCHEMA_PATH points to an invalid location".
          • How To Set Reducer Size Annotation for Bill Of Material Report in OpenPlant Isometrics Manager
          • How To Set Reducer Size Annotation in BOM Report OPIM CE
          • How to Show 3 Port Information PIPE_LATERAL_TEE_REDUCING_ONE_RUN_AND_BRANCH in Isometric Drawing
          • How to Show Calculated Pipe Weight for Bill Of Material in OpenPlant Isometrics Manager
          • To Fix Bend Angle Precision value in OpenPlant Isometrics Manager
          • How to Show Pipe Support Coordinates in OpenPlant Isometrics Manager
          • To Resolve Bolt Length Conversion Issue in OpenPlant Isometric Manager
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    To exclude Existing fittings' Part-IDs or to reset Part-IDs

    Applies To
    Product(s): OpenPlant Isometrics Manager
    Version(s): CONNECT Edition (10.09.00.74)
    Environment: Windows 10 (64 bit)
    Area: Configuration
    Subarea:  BOM
    Original Author: Soham Mhaskar, Bentley Product Advantage Group

    Overview

    This wiki will be helpful in case when existing fittings part-IDs are to be excluded.

    Steps to Accomplish

    1. Open Bentley Class Editor CONNECT Edition.

    2. Open OpenPlant 3D schema and Supplement it with Modeling, Modeling Views and IsoExtractor schemas.

    3. Go to “Plant Base Object” Class.

    4. Edit the following in “Default Bill of Material Labels” custom attribute.

    Copy from here: llf(IM.Match(this.STATE."EXISTING"."FOR_DEMOLITION"."").1.0)

     This will help you resolve not one but two issues: Excluding Existing components from OPIM BOM and resetting Part IDs thereafter.

    See Also

    Logic for Shop and Field welds in OPIM CE
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): CONNECT EDITION (10.09.00.74) Environment: Windows 10 (64 bit) Area: Configuration Subarea: …
    Last edited over 1 year ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Still a Problem?

    If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • OPIM CE
    • BOM
    • PART ID
    • existing
    • Share
    • History
    • More
    • Cancel
    • Soham Mhaskar Created by Bentley Colleague Soham Mhaskar
    • When: Mon, Mar 29 2021 1:59 AM
    • Soham Mhaskar Last revision by Bentley Colleague Soham Mhaskar
    • When: Mon, Mar 29 2021 1:59 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies