Many user has raised the issues about getting bolt length inaccurately due to regional setting changes in Mixed Metrix Project via following this Wiki.:
Below steps would help user to resolve his query by creating correct style folder.
Many time OPM CE version is used with different regional setting and in that the major changes include about changing of decimal separator from ,”dot” to ,”comma”.Hence the bolt Length issues changes as shown in problem description.If the decimal separator ,”dot” is used then we get perfect result.
include = EC_CLASS=STUD_BOLT
@@SIZE2 = BOLT_LENGTH:#
After adding new rule save the overrides.txt and again generate the isometric.Required bolt length in mm will get reflected as shown in image below :Thus the issue for inaccurate bolt length getting reflected due to regional setting can be resolved.
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!