OpenPlant | AutoPLANT Wiki How to create display rules for specified class in PlantSight Visualizer
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • -OpenPlant CONNECT Edition-PlantSight Integration
          • Fundamental of Tag Management using PlantSight Portal for OpenPlant CONNECT Update 9
          • [FAQ] - PlantSight
          • How to Convert IFC Format in PlantSight
          • How to Add New Associated Item Class for OpenPlant PID CONNECT Edition-PlantSight Integrated WorkSet
          • How to add PlantSight equipment Tag for MicroStation graphics
          • How to Change Measurement Unit in PlantSight Visualizer used in Measuring Element.
          • How to Clear Reserved Tags from OpenPlant in EDM
          • How to Create a new Role in the Project & Assign it to the User/Client.
          • How to create display rules for specified class in PlantSight Visualizer
          • How to Create Issue for Specified Component in Plantsight Visualizer
          • How to create saved view in PlantSight.
          • How to Enable Release Tag Services for PlantSight User
          • How to Fetch iModel Information Details for a PlantSight Integrated Workspace in OpenPlant Modeler Update 8
          • How to Generate Equipment Data-Sheet for Equipment in Engineering Data Manager
          • How to Perform Selective Check-in into OpenPlant Modeler CONNECT Edition
          • How to Place a Tag for Custom Equipment created in OpenPlant Modeler with reference to OpenPlant P&ID & Plantsight.
          • How to Push New Schema Changes to Already Provisioned PlantSight WorkSet for OpenPlant Modeler CONNECT Edition
          • How to Put Filter on Properties in Tag Browser Of Tag Management in Data Manger in PlantSight
          • How to Reference out the components by Volume OpenPlant Modeler
          • How to Resolve the error while Importing the Excel back after editing in PlantSight Project.
          • How to Resolve the issue of Miscellaneous Equipment in OpenPlant PID, which is not able to Check-in to Plantsight.
          • How to Show/Enlist Newly Added Derived Class in PlantSight Tag Management Portal
          • How to Solve the Error when the Tag is not able to Browse in OpenPlant Modeler/PID from Plantsight / Engineering Data Manager.
          • How to Turn-Off PlantSight Differences Dialog Upon Check-in OpenPlant 3D Model to PlantSight
          • How to Update Component Properties from Process Drawing to 3D Components in OpenPlant Modeler CONNECT Edition
          • How to Update Existing Schema Changes to Already Provisioned PlantSight Workset for OpenPlant Modeler CONNECT
          • How To Upload .pod File Format of Reality Data into iModel and view into it in PlantSight
          • How to use Bentley Template when creating PlantSight Project
          • To Fix Issue of OPPID Dgn throwing Work Offline Dialog box Eventhough Workset Associated to PlantSight
          • How to Create Folder in PlantSight Project Shared Files
          • How to hardcode UOM of properties in Advanced Query EDM
          • How to Integrate OpenPlant PID with OpenPlant Modeler Using PlantSight
          • How to Sync i.dgn to PlantSight
          • To Customize Query Results in Engineering Data Manager
          • To Show Tie-in in PlantSight Viewer
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
        • To Clean Residual Files After Uninstalling OpenPlant
        • To Fix Dialog not Showing After Disconnecting Multiple Monitor Display
        • To Fix Error "A required privilege is not held by the client" When Generating External Reports
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!
    • Learning Content for OpenPlant

     
     Questions about this article, topic, or product? Click here. 

    How to create display rules for specified class in PlantSight Visualizer


    Applies To 
    Product(s): OpenPlant Modeler
    Version(s):

    CONNECT Edition 10.09.00.74

    Environment:  Windows 8.1/10 (64-bit)
    Area:  Data Visualization
    Subarea:   PlantSight Integrated WorkSet
    Original Author: Aishwarya Kulkarni,Bentley Product Advantage Group


    Background

    In this wiki article, we will explore How to create display rules for specified class in PlantSight Visualizer.

    Steps to Accomplish

     A. Pre-requisite

    1. To use the visualizer portal, we need to have PlantSight registered project.
    2. WorkSet must be associated and Setup with a PlantSight project.
    3. Ensure that desired applications are enabled for workset like OpenPlant Modeler and OpenPlant PID."

      Note:Provision tool has rebranded as Setup in OpenPlant Update 9. Refer image as shown below.





    B.Loading visualizer portal and create display rules for a specified class   
         

    1. Load OpenPlant Project Administrator.
    2. Select an associated workset and from the Project Portalsribbon group and select PlantSight. Refer to the image below.



    3. Enter login credentials if prompted.
    4. Once logged in successfully, notice the in left-hand pane, visualizer service is enlisting as shown in below


    5. Click on Visualize and navigate 3D models. Select the imodel and click on enter imodel as shown below.




    6. In the imodel, click on the Data Visualization as shown below




    7. Click on add icon to create a display rule. Refer below image
       




    8. In Edit Data Visualization add name as Test. Click on the drop-down list, chose Equipment as a class and Description as property. Click on Generate as shown below image




    9. After generating the label, specify the color as per your project requirement and click on save. Refer below image



    10. Go back to Data Visualization and click on the Test display rule. Refer below image




      In the PlantSight, it is showing the same color as mention in the display settings.


    See Also 

    How to add the Reattach Instrument Bubble and Annotation option in the OpenPlant PID
    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 8.1/10 (64-bit) Area: Ribbon Customization Subarea…
    Last edited over 1 year ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    • OPM modeler CE
    • data visualization
    • PlantSight Modeler Visualizer Node
    • display rules
    • Share
    • History
    • More
    • Cancel
    • Aishwarya Kulkarni Created by Aishwarya Kulkarni
    • When: Mon, May 3 2021 3:54 AM
    • Rahul Kumar Last revision by Bentley Colleague Rahul Kumar
    • When: Thu, Sep 1 2022 2:03 PM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies