Sometimes user may face this issue while working with AutoPLANT Modeler and OpenPlant Isometric Manager. While generating the isometric drawing, it cannot generate the isometric drawing with specified drawing file. Even though selected manually or advance. It does not export the data and displays following isometric export progress dialog.
This wiki article explains the steps to resolve this issue.
1.Before following the below steps, make sure to take the backup of the project
2.Open the corrupted drawing file and run the following command in command line
(AT_PIPINGSYSTEM_SETVARIABLE "NORTH_DIRECTION" "90.0")
Note: Command should run along with brackets.
3.Save the file and generate the isometric.
AutoPLANT - OpenPlant Isometrics Manager CONNECT Edition OpenPlant Isometrics Manager CONNECT - AutoPLANT See Also AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to… Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.