When there is issue moving an Equipment, there may be a case of corrupt Nozzle Definitions. In this case, just export and import the Nozzle Definitions of the particular Equipment to have this issue resolved.
1. Open Nozzle Manager and select the concerned Equipment. Export all the existing Nozzle Definitions.
2. Save it to a location.
3. Go back to Nozzle Manager and remove all the nozzles one by one for concerned Equipment.
4. Reload the Nozzle Definition which was saved, for the same concerned Equipment.
5. Apply changes, validate record from specs and now try to move the equipment. It will work.
To populate Shop in existing Component’s Shop Field Applies To Product(s): OpenPlant Modeler Version(s): CONNECT EDITION (10.09.00.74) Environment: Windows 10 (64 bit) Area: Configuration Subarea: Original… Last edited over 1 year ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!