In a Mix Metric project, while working with equipment module when editing the equipment vessel dialog box shows all units converted to ft. Since this is a Mix Metric project units should be metric except for Nozzles NPS.
This wiki article explains the steps to resolve this issue.
1.Open the Config.ini file from the project directory (here we have used Sample MMETRIC Project)
C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_MMETRIC\Config
2.Open the config.ini file and change the value of ARCH_UNIT_DISPLAY variable to 0 from 1
After changing this variable value user will be able to see the Equipment Units in Metric unit.
AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to-use 3D plant design and modeling software The applications included in AutoPLANT Modeler CONNECT Edition suite are AutoCAD-based… Last edited 5 months ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki