Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki To Fix Issue of OPPID Dgn throwing Work Offline Dialog box Eventhough Workset Associated to PlantSight
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • -OpenPlant CONNECT Edition-PlantSight Integration
          • Fundamental of Tag Management using PlantSight Portal for OpenPlant CONNECT Update 9
          • [FAQ] - PlantSight
          • How to Convert IFC Format in PlantSight
          • How to Add New Associated Item Class for OpenPlant PID CONNECT Edition-PlantSight Integrated WorkSet
          • How to add PlantSight equipment Tag for MicroStation graphics
          • How to Change Measurement Unit in PlantSight Visualizer used in Measuring Element.
          • How to Clear Reserved Tags from OpenPlant in EDM
          • How to Create a new Role in the Project & Assign it to the User/Client.
          • How to create display rules for specified class in PlantSight Visualizer
          • How to Create Issue for Specified Component in Plantsight Visualizer
          • How to create saved view in PlantSight.
          • How to Enable Release Tag Services for PlantSight User
          • How to Fetch iModel Information Details for a PlantSight Integrated Workspace in OpenPlant Modeler Update 8
          • How to Generate Equipment Data-Sheet for Equipment in Engineering Data Manager
          • How to Perform Selective Check-in into OpenPlant Modeler CONNECT Edition
          • How to Place a Tag for Custom Equipment created in OpenPlant Modeler with reference to OpenPlant P&ID & Plantsight.
          • How to Push New Schema Changes to Already Provisioned PlantSight WorkSet for OpenPlant Modeler CONNECT Edition
          • How to Put Filter on Properties in Tag Browser Of Tag Management in Data Manger in PlantSight
          • How to Reference out the components by Volume OpenPlant Modeler
          • How to Resolve the error while Importing the Excel back after editing in PlantSight Project.
          • How to Resolve the issue of Miscellaneous Equipment in OpenPlant PID, which is not able to Check-in to Plantsight.
          • How to Show/Enlist Newly Added Derived Class in PlantSight Tag Management Portal
          • How to Solve the Error when the Tag is not able to Browse in OpenPlant Modeler/PID from Plantsight / Engineering Data Manager.
          • How to Turn-Off PlantSight Differences Dialog Upon Check-in OpenPlant 3D Model to PlantSight
          • How to Update Component Properties from Process Drawing to 3D Components in OpenPlant Modeler CONNECT Edition
          • How to Update Existing Schema Changes to Already Provisioned PlantSight Workset for OpenPlant Modeler CONNECT
          • How To Upload .pod File Format of Reality Data into iModel and view into it in PlantSight
          • How to use Bentley Template when creating PlantSight Project
          • To Fix Issue of OPPID Dgn throwing Work Offline Dialog box Eventhough Workset Associated to PlantSight
          • How to Create Folder in PlantSight Project Shared Files
          • How to Sync i.dgn to PlantSight
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    To Fix Issue of OPPID Dgn throwing Work Offline Dialog box Eventhough Workset Associated to PlantSight


    Applies To 
    Product(s): OpenPlant CONNECT Edition
    Version(s):

    10.09.00.74 Update U9.

    Environment:  Windows 10 (64-bit)
    Area:  Plantsight+ OPPID
    Subarea:  Sync Option /Work Offline
    Original Author: Ashutosh Patil, Bentley Product Advantage Group

    Problem Description

    Many user has raised the issues about getting Working Offline dialog box whenever they launch the dgn eventhough their workset is connected to PlantSight project as shown in image below:



    Working Offline dialog box is popped up when Dgn gets launch.



    Sync option in OPPID dgn when  launched entirely it is faded as shown below  



    There are many other cases when dgn gets into offline mode when launched, and in this article one of it has been explained.

    Reason:

    First check kindly verify that Workset is properly associated to Plantsight project through OPPA .
    For that go to Workset.cfg, For this wiki OOTB Imperial workset has been considered and its path is shown below :

    C:\ProgramData\Bentley\OpenPlant CONNECT Edition\Configuration\WorkSpaces\OpenPlantExample\WorkSets

    Rightclick on Imperial.cfg and open with Notepad or Notepad++.



    Verify that into Imperial.cfg there is no value assigned infront of iModel file and its Guid since it is not been linked properly eventhough workset has been Associated to PlantSight Project



    Go to OPPA same workset-Imperial and on rightside window pane in Connected Project Information entities: It can be found that iTwin of the PlantSight project has not been linked hence infront of iTwin file & iTwin GUID it is Not Defined as highlighted in red in below image.




    Solution:  

    To rectify the issue kindly follow below step:

    1. When we associate a Workset to PlantSight project the cap besides Imperial workset shown below turns into Darkgreen from yellow .



    2.If you are an admin you can do set up of that workset further and verywell aware of how to do setup  of that Plantsight Itwin..



    Kindly view the wiki attached at the end of this article.

    3.But if Admin has already done the Setup for that workset then other user need to proceed with Link to iTwin option in CONNECT Service tab



    4.But as a User just click on link to iTwin then Select an Already Setup iTwin dialog box will be popped up hit on Yes.



    5.Select iTwin dialog box will pop and show iTwin into the Associated PlantSight project.

    (Cross is the name given to our iTwin file created in PlantSight Project for which the workset has been associated)



    6.After hitting on Select in last step within few seconds it will give Workset,’Imperial’ successfully connected to Cross  iTwin  as shown below.

    (Cross is the name given to our itwin file created in PlantSight Project for which the workset has been associated)



    7.On right hand side pane  of workset - Imperial in CONNECTED Project Information section iTwin File and iTwin Guid gets reflected as shown below.



    8.Same values gets reflected into Imperial.cfg for IMODEL_FILE & IMODEL_GUID  as shown in image below



    Note: Make sure during this above procedure, OPPID dgn which was showing working offline dialog box is closed

    Result: 

    After Link to iTwin is done launch the same dgn connected to that workset.During launching it will show the proper itwin Name  or iModel Name to which it is connected.
    Hit on yes



    And after dgn is launched completely it can be seen that Sync and Setting option is enabled.



    Thus with this one case of dgn getting into Working Offline mode can be resolved.

    See Also

    Difference between Setup, Upgrade and iModel Link in OpenPlant Project Administrator CONNECT Update 9...
    Applies To Product(s): OpenPlant Project Administrator Version(s): CONNECT Edition 10.09.00.74 Environment: Windows 8.1/10 (64-bit) Area: CONNECT Services Subarea…
    Last edited over 1 year ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Still a Problem?

    If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround

    • working offline
    • work offline dgn
    • Link to iTwin
    • OPPA CE
    • OPPID U9 CE working offline dialog box
    • Share
    • History
    • More
    • Cancel
    • Ashutosh Patil Created by Bentley Colleague Ashutosh Patil
    • When: Tue, Sep 28 2021 2:20 PM
    • Rahul Kumar Last revision by Bentley Colleague Rahul Kumar
    • When: Thu, Sep 1 2022 2:03 PM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies