Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Set Decimal Accuracy in Annotation label for Nominal Diameter and Insulation Thickness Property in OpenPlant Modeler Connect
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • -OpenPlant Modeler CONNECT
          • +[FAQ] - OpenPlant Modeler CONNECT Edition
          • +What's New in OpenPlant Modeler CONNECT Edition
          • +Resolved issues in OpenPlant Modeler CONNECT Edition Releases
          • +Errors, Logs, Messages, Crashes in CONNECT - OpenPlant Modeler
          • How to Add Columns to In-Drawing Reports in OpenPlant Modeler
          • How to Add Dimensional Unit to Added Property in OpenPlant Modeler CONNECT Edition
          • How to add facing property on the nozzle of the equipment in OpenPlant Modeler CONNECT Edition.
          • How to add inch text or sign with nominal diameter in OpenPlant Modeler CONNECT Edition.
          • How To Add New Property and Define A Calculated Formulae in that Property
          • How to add property in column grid of nozzle manager dialogue in OpenPlant Modeler CONNECT Edition.
          • How to Automate Desired Port Setting for Placement of HVAC Round Components in OpenPlant Modeler CONNECT Edition Update 7
          • How to bring OpenPlant PID 2D data in 3D OpenPlant Modeler
          • How to Cascade Line Number Property to Support & Associated Support in OpenPlant Modeler CONNECT Edition.
          • How to Change Branch Angle for Pipe Lateral Tee Fitting in OpenPlant Modeler CONNECT Edition
          • How to change Decimal Dimensional value of Pipe Length in OPM CE
          • How to change device type code in OpenPlant Modeler CONNECT EDITION.
          • How to Change pipeline symbology according to service in OpenPlant Modeler CONNECT Edition.
          • How to Change the Precision Level of Dimensions on Components in OpenPlant Modeler CONNECT Edition.
          • How to change Weld Size in OpenPlant Modeler CONNECT Edition.
          • How to Configure OpenPlant Modeler to Allow Component Placement with Different Facings
          • How to Configure OpenPlant Modeler to Allow Flange Connection with Different Facings.
          • How to Configure OpenPlant Modeler To Allow Flange Connection With Different Ratings.
          • How to automate offset for Valve Operator Handle in OPM CE
          • How to Create a Managed WorkSet from a custom template using OpenPlant Project Administrator
          • How to Create a New Joint Type Using OpenPlant Project Administrator CONNECT Edition
          • How to Create Association for OpenPlant Modeler CONNECT using OpenPlant Project Administrator CONNECT
          • How to Create DGN Reports in OpenPlant Modeler
          • How to Create Managed WorkSpace Manually For OpenPlant Modeler CONNECT Edition
          • How to Create Managed WorkSpace Manually for OpenPlant Modeler CONNECT Edition : CSB Assignment
          • How to Create Managed WorkSpace Manually for OpenPlant Modeler CONNECT Edition : CSB Definition
          • How to Create Managed WorkSpace Manually for OpenPlant Modeler CONNECT Edition : Folder Management
          • How to Create NipoFlange in OpenPlant Modeler CONNECT Edition.
          • How To Create Reinforced Branch Connection Types Using Branch Table
          • How to Create Repository of the Structure in OpenPlant Modeler Connect Edition
          • How To Create Reserved Area In OpenPlant Modeler.
          • How to Create Sheet through Named Boundary in OpenPlant Modeler CONNECT Edition
          • How to Create surface member by desired shape in OpenPlant Modeler Connect Edition.
          • How to Customize Existing Annotation Label in OpenPlant Modeler CONNECT
          • How To Detect Clashes between pipelines in a Model using OpenPlant Modeler
          • How To Enable Level Gauge class as Custom Component .
          • How to Fetch Description Value from Specification Database for Supports in OpenPlant Modeler CONNECT
          • How to Format Default Number Property in OpenPlant Modeler CONNECT Edition
          • How to Generate Configuration Variable Report in OpenPlant Modeler CONNECT Edition
          • How to get a Kink on a Pipe without generating Welds in OPM CE
          • How to get PIECE MARK information from Spec on all Piping Components in OPM CE
          • How to Import Pipeline list & its Properties from Excel Sheet in OpenPlant Modeler CONNECT
          • How to Import STEP(.stp) File into OpenPlant Modeler CONNECT Edition.
          • How to Include Bend Working Point Coordinate in OpenPlant Modeler Connect Edition.
          • How to include line number in report of supports.
          • How to Merge Multiple Smart Line Using Intelligent Line and Convert into One Pipeline in OpenPlant Modeler CONNECT Edition
          • How to modify any piping component in Bulk via OpenPlant Modeler CONNECT Edition.
          • How To Perform Check-in /Check-out operation in OpenPlant Modeler Connect Edition and view in PlantSight Portal.
          • How to Place a Pipe Support on TEE and get it in Iso Output
          • How to place a Tap on Blind Flange center in OPM CE
          • How to Place Different Types of Flanges Automatically for Component Assembly in OpenPlant Modeler CONNECT Edition
          • How to Place Pipeline Using Intelligent Line in OpenPlant Modeler CONNECT Edition
          • How to Place Trimmed Elbows Having Flanged Ends in OpenPlant Modeler.
          • How to Preview Reports of Placed Components in OpenPlant Modeler
          • How to Remove Compatibility Check for Material Upon Placing Component in OpenPlant Modeler
          • How to Setup & Use OpenPlantSDK Examples in OpenPlant Modeler
          • How to show Centerline on HVAC Duct In OpenPlant Modeler CONNECT Edition.
          • How to Show Section & Material Details for Structural Component in OpenPlant Modeler CONNECT Edition
          • How To Update Bolts And Gaskets In OpenPlant Modeler Connect Edition
          • How To Use Break Command in OpenPlant Modeler
          • How to Use External Database Query Custom Attribute in OpenPlant Modeler CONNECT Edition
          • How to View Markups in OpenPlant Modeler CONNECT Edition
          • How to Visualize properties of Revit Model (i.dgn file) using PlantSight Visualization option
          • How to Zip Complete WorkSpace for OpenPlant Modeler
          • How to Customize the Pop-up Tool Box in OpenPlant Modeler CONNECT EDITION.
          • +Import-Export - OpenPlant Modeler CE
          • +OpenPlant Modeler Synchronization to iModelHub
          • +ProjectWise - OpenPlant Modeler CONNECT Edition
          • +Settings/Attributes - OpenPlant Modeler CE
          • To Assign Spool Number for Small Bore Size Component in OpenPlant Modeler
          • To Create a New Component State in OpenPlant Modeler
          • To Fix no Weld issue when placing Thredolet
          • Unable to place Tap on Blind Flange Center or Face in OPM CE
          • How to add OpenPlant Support Engineering Tools on OpenPlant Modeler Interface.
          • How to Add Plate Type Flange Class Component in OpenPlant Modeler connect.
          • How To Annotate Reducing Fitting through Text Favourite Manager using Place Note in OpenPlant Modeler CONNECT Edition
          • How to Apply Slope on Straight Pipeline Along with Inline Components on it in OpenPlant Modeler CONNECT Edition
          • How to Assign Levels based on Equipment Type Using Named Expression in OpenPlant Connect Edition
          • How to Assign Resource to Work Area to Load Specified Application & its Association for OpenPlant Modeler CONNECT
          • How to Associate the Specification Based on Service in OpenPlant Modeler Connect
          • How to change Folder location from Workset level to Organization Level in OpenPlant Modeler
          • How to change the background color of preview dialogue.
          • How to Configure OpenPlant Modeler CONNECT Edition to Use Workspace from Shared Location.
          • How to control specific record during autofitting of component in OpenPlant Modeler CONNECT Edition
          • +How to Create & Place a Custom Angle Pipe Elbow.
          • How to Create a Custom Joint in OpenPlant Modeler Connect
          • How to Create a Steam Trap Component by Using Custom Graphics in OpenPlant Modeler Connect Edition
          • How to Create Custom Ribbon Group, Custom Tool Button & Gallery in OpenPlant Modeler CONNECT
          • How to create Four Port Components with different sizes in OpenPlant Modeler.
          • How to Create Four Ports Component with Different Sizes in OpenPlant Modeler Connect
          • How To Create New Associated Property Using Class Editor in OpenPlant Connect Edition
          • How to Create Search Criteria to Include Properties from Fluid Port in OpenPlant Modeler Connect
          • How to Create WeldoFlange in OpenPlant Modeler.
          • How to Disable ProjectWise Desktop Integration with OpenPlant Modeler Connect
          • How To Display Level Name and Symbology For HVAC Components in OpenPlant Modeler CONNECT EDITION
          • How to enable Bentley Raceway and Cable Management tools for OpenPlant Modeler
          • How to Enable Elbow Grid Selection Dialog box during AutoFitting placement in OpenPlant Modeler CONNECT Edition
          • How To Enable Placement of Child Classes of Any Component in OpenPlant Connect Edition.
          • How to Export Metada from imodel of OpenPlant Modeler to Access.mdb file.
          • How to Fix Generic Valve Insertion Issue in OpenPlant Modeler Connect
          • How to Generate Isometric Insession & Outsession in CONNECT Edition.
          • How to Get Inside Diameter Calculated in OpenPlant Modeler Connect
          • How to hide/unhide Specific component in OpenPlant Modeler.
          • How to Include End Condition in OOTB Valve Reports through Reporting Designer in OpenPlant Modeler Connect Edition
          • How To Map Custom Double Type Property in OpenPlant Modeler Connect
          • How to Match Different Nominal Diameters for Flanged Connection in OpenPlant Modeler CONNECT Edition
          • How To Model Custom PIPE_WYE 30DEG RUN-BRANCH Angle in OpenPlant Modeler
          • How to Modify Default Outside Diameter Value for End Types in OpenPlant Modeler connect
          • How to Modify Hand Wheel Stem Thickness in OpenPlant Modeler CONNECT
          • How To Pick Nozzle Length From Spec Database in OpenPlant Modeler Connect
          • How to Place an Isometric Break Point in OpenPlant Modeler CONNECT
          • How to Populate Workset Name on EC Property For Components in OPPID & OPM CONNECT Edition U9.
          • How to Review AutoPLANT Objects in to AutoCAD-MicroStation-OpenPlant
          • How to Save Parametric Equipment in ec.Model.xml File.
          • How to Set Decimal Accuracy in Annotation label for Nominal Diameter and Insulation Thickness Property in OpenPlant Modeler Connect
          • How to Set Pipeline in Items Node of Explorer in OpenPlant Modeler CONNECT Edition
          • How to Surpass the Solids Accuracy Dialogue.
          • How To Use Detail Callout and Place detail callout in OpenPlant Modeler Connect Edition
          • How to Use Sync to ITwin feature in OpenPlant Modeler.
          • How To Utilize Place Custom Equipment Option in Consistency Checker in OPM CE
          • To Define start point of Spool ID in OpenPlant Modeler
          • To Fix Placement of Operator on Valves in OpenPlant Modeler Connect Edition
          • To Obtain Arc Length for Pipe Elbows in OpenPlant Modeler
          • To populate Shop in existing Component’s Shop Field
          • Unable to Load Document with MicroStation using Managed WorkSpace of OpenPlant Modeler CONNECT
          • How to fix the disconnects with a selection from the spec grid.
          • +How to Add a ShareFile Network Custom Configuration Root within OpenPlant Modeler Update 11
          • How to Add a Weldneck Stub End in OPM CE
          • How to add column from specs in component selection dialog box
          • How To Add Custom Valves in Schema for OpenPlant Modeler Connect Edition
          • How to Apply Dark Theme to OpenPlant Modeler Interface.
          • How to Auto Place Victaulic Coupling on Pipe to Pipe connection in OpenPlant Modeler.
          • How to automate offset of Valve operator Handwheel in OPM CE
          • How to Configure LookupMap from Local Folder to ProjectWise
          • How to Control Component Symbology based on Design State or Component State via Named Expression
          • How to Create Search Criteria to Include Properties from Fluid Port in OpenPlant Modeler CONNECT Edition
          • How to differentiate between multiple records for TopWorks in Spec
          • How to Disable Component Gallery in OPM CE
          • How to Disable the Prostructures Tools from OpenPlant Modeler Interface.
          • How to enable ProStructures as seperate license with OpenPlant Modeler Update 9?
          • How to Fix Bolt Joint Type Connections in Open Plant Modeler
          • How to Fix Disconnects by Picking Seal and Fastener from Spec Grid in OpenPlant Modeler Connect Edition
          • How to Include XYZ Coordinates in Reports for Piping Components in OPM CE
          • How To Manage Rubber Lined Gasket in OpenPlant Modeler
          • How to Map Spec Table for Placement of Missing Component in OpenPlant Modeler Connect Edition
          • How to Match Different Nominal Diameters for BUTT WELD Connection in OpenPlant Modeler.
          • How To Pick Nozzle Length From Spec Database in OpenPlant Modeler CONNECT Edition
          • How to Place Components by Actual Pipe Size Instead of Nominal Diameter in OpenPlant Modeler CONNECT Edition
          • How to Place Flow Arrows on Pipe in OpenPlant Modeler.
          • How to place Place Revision Cloud by the element in OpenPlant Modeler Connect Edition
          • How to Preserve Original Number Value upon paste of Components in OpenPlant Modeler CONNECT Edition
          • How to Resolve Pipe Note Tooltip displays Default Text
          • How to set the sequence of properties in Spec Selection Grid via Schemas.
          • How to snap OPM piping component to the edge of it
          • How to unlock the multiple components in OpenPlant Modeler CONNECT Edition
          • How to use Custom Component Gallery in OpenPlant Modeler
          • How to use Different Facing Instead of Default Raised/Flat Face Facings in OpenPlant Modeler CONNECT Edition
          • Key-in & Configuration Variables for OpenPlant Modeler CONNECT Edition
          • Place Revision Cloud via Key-in OpenPlant Modeler Connect Edition
          • ProStructures as Add In in OpenPlant Modeler CONNECT Edition.
          • Release Notes - OpenPlant CONNECT Edition
          • To casade pipeline property values to Fasteners
          • To fix issue of Bolts not appearing on auto flange sets in OPM CE
          • To Resolve BimAdapterNative.dll issue while loading Standard Preference dialog
          • To Resolve Column Gridline Issue in OpenPlant Modeler Connect Edition
          • To Resolve if there is no Workspace and Workset Visible While Launching OpenPlant Modeler
          • To Resolve selecting Half Coupling also displays Full Coupling in OPM
          • To Resolve Unable to Resize Column Widths in Consistency Manager Properties section
          • To Stop Initializing Structural Modeling Component in OpenPlant Modeler MicroStation Connect Edition
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    How to Set Decimal Accuracy in Annotation label for Nominal Diameter and Insulation Thickness Property in OpenPlant Modeler Connect


    Applies To 
    Product(s): OpenPlant Modeler Connect
    Version(s):

    CONNECT Edition 10.09.00.74 (Update 9)

    Environment:  Windows 8.1/10 (64-bit)
    Area:  Schema
    Subarea:  Annotation 
    Original Author: Aishwarya Kulkarni, Bentley Product Advantage Group


    Background

    In OpenPlant Modeler, the requirement is to fetch the multiple properties of the piping components in the annotation. At the time of placement annotation, the properties value gets some extra space and label accuracy is set to active settings (6 digits) for nominal diameter and insulation thickness. This wiki article explains the procedure for how to remove those extra spaces from annotation and how to set decimal accuracy.





    Steps to Accomplish

    1. Launch Bentley Class Editor,
    2.  For the desired workset location, select 01.08schema & click on Open to load the schema. Supplement the loaded schema with Supplemental schemas.

      Refer the attached Wiki link to know, How to Load & Supplement Schema in Bentley Class Editor

      Click Here(attach link)

    3. Navigate to PIPING COMPONENT class, switch Property Tab. Refer below image




    4. Click on Add > New to create a new property. Refer image below.



    5. Enter property details for newly created property as shown below.



    6. Right click on newly created property here DEMO_1  & select Custom Attributes > Add/Remove to add custom attribute as shown below.



    7.  Search for Calculated ECProperty Specificationcustom attribute & using down arrow add this custom attribute. Ensure to change schema location for this applied custom attribute as shown below.



    8.  Enter details for applied Calculated ECProperty Specification custom attribute as shown below

      ECExpression: this.PLANT_AREA & "-" & this.SERVICE & "-" & this.SPECIFICATION & "-" & System.Math.Round(this.NOMINAL_DIAMETER,0) & "-" & this.INSULATION & System.Math.Round(this.INSULATION_THICKNESS,0)

        


    9. Add Category Custom Attributes and enter the details as shown below



    10. Save all the changes & verify the result in OpenPlant Modeler. 



    11. Navigate the EC Annotation cell file.

      C:\ProgramData\Bentley\OpenPlant CONNECT Edition\Configuration\Workspaces\OpenPlantExample\WorkSets\Imperial\Standards\OpenPlant\Modeler\Cell



    12. Navigate the models and copy-paste the pipeline tag. Add model name as a DEMOTAG.
            
    13. Navigate the text and click insert favorite as shown below 

           

    14. From manage create one text favorite as shown below. Add newly created property here DEMO_1.
             


    15. Save all the changes in Text favorite Manager.

    16. From Text Editor, select newly created text favorite as shown below.



    17.  Attached is text in DEMOTAG model.


        
    18. Launch open Plant modeler and click on place label. Select the created cell DEMOTAG and place lace label as shown below 



      Now observe the decimal accuracy for nominal diameter and insulation thickness.


      Note: Please note that if you have existing modeling components then we would recommend using the existing property like Alias from Piping Component level and do the changes.

    See Also

    How to Get Inside Diameter Calculated in OpenPlant Modeler Connect
    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 8.1/10 (64-bit) Area: Schema Subarea: Property…
    Last edited over 1 year ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    • OpenPlant Modeler
    • System math
    • Annotations
    • OPM CE U8
    • schema
    • Property Mapping For Double Property
    • Share
    • History
    • More
    • Cancel
    • Aishwarya Kulkarni Created by Aishwarya Kulkarni
    • When: Wed, Oct 27 2021 4:06 AM
    • Rahul Kumar Last revision by Bentley Colleague Rahul Kumar
    • When: Tue, Mar 15 2022 11:22 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies