Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenPlant | AutoPLANT
  • Product Communities
  • More
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to include custom schema in OpenPlant PID under component manager
    • Sign in
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • -OpenPlant PID v8i
          • +Application Solutions - OPPID
          • +Class Editor - OpenPlant PID
          • +Customization - OpenPlant PID
          • +Database - Plant Project
          • How to Cascade Associated Item's Value from Associated Class to Fitting Class in OpenPlant PID V8i
          • How to cascade Associated Items value from Pipeline to Reducer using Notifier in OpenPlant PID V8i
          • How to Change the Existing Cell Component Graphics in OpenPlant PID V8i
          • How to Fix Modified Tag Value Upon Second Sync in OpenPlant PID V8i
          • How to Hide the Actuator Prompt for Control Valve in OpenPlant PID V8i
          • How to include custom schema in OpenPlant PID under component manager
          • How to Point Custom WorkSpace Location in OpenPlant PID SS10
          • How to set the Fail Mode List for control valve Placement in OpenPlant PID V8i
          • +Properties - OpenPlant PID
          • +Release Notes - OpenPlant PID
          • +Training - OpenPlant PID
          • +White Papers/Guidelines - OPPID
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    How to include custom schema in OpenPlant PID under component manager

    Applies To
    Products(s): OpenPlant PID V8i
    Version(s): 08.11.12.03 (SS10)
    Environment Windows 7/8.1/10 (64 bit)
    Area Customization
    Subarea Component Manager
    Original Author Neha Chougule, Bentley Product advantage Group

    Background

    Component Manager includes PID schema only. Now the requirement is to add custom schema in OpenPlant PID under component manager. Follow the below wiki to meet the requirement.



    Steps To Accomplish

    1. Go to PID configuration - pid.cfg in following below mentioned location.

      C:\Program Files (x86)\Bentley\OpenPlantPID (SS10)\OpenPlantPID\config\appl



    2. Right Click the pid.cfg and Edit with Notepad++.



    3. Enter the desired custom schema name. Refer image below.

      BMF_COMPONENT_MANAGER_SCHEMAS < {desired custom schema name}



    4. Save all the changes and load OpenPlant PID.



    5. Go to Component Manager and notice that custom schema gets enlisted as shown below.




    See Also

    Comments & Corrections

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    • schema customization
    • OpenPlant PID
    • Component Manager
    • v8i
    • OPPID
    • custom schema
    • schema
    • new schema
    • Share
    • History
    • More
    • Cancel
    • Neha Chougule Created by Bentley Colleague Neha Chougule
    • When: Wed, Nov 17 2021 11:56 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies