While working with AutoPLANT Modeler and OpenPlant Isometrics Manager CE, when generating an isometric drawing for Sample default project of AutoPLANT Modeler. The isometric drawing generates fine but when checking isometric output, there is an error in the message center as “invalid seed file” appears. This wiki article explains the steps to resolve this issue.
1.Go to the below directory
C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant\Isometrics
2.Open IsoProj.cfg file
3.Add MS_TRANSEED_OVERRIDE=2 variable as shown in below snapshot.
4.After adding this variable, user will be able to generate the isometric drawing without getting any error message.
AutoPLANT - OpenPlant Isometrics Manager CONNECT Edition OpenPlant Isometrics Manager CONNECT - AutoPLANT See Also AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to… Last edited over 4 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki