By default bill of material categorizes shop field and field weld material in OpenPlant Isometrics Manager, however the user may customize the field material report under shop material.
The article will guide how to add field material under shop material.
REPORT = SHP # this to include only shop material INCLUDE = IE_FIELD = 0 INCLUDE = IE_FIELD = 1 EXCLUDE = IE_TYPE = CT_WELD
COLUMN = 3: R : PARTID COLUMN = 19: C : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 60: W : IE_DESCRIPT
GROUP = PARTID SORT = PARTID:N SEP = @ SORTHEADERS = 1
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12642.configuring-the-bom-and-reports