Background
In OpenPlant Modeler CE, the requirement is to configure LookupMap from a local folder to ProjectWise
Steps to Accomplish
- Copy the LookupMap.txt file from the Local folder to your linked WorkSet with ProjectWise.
Path: C:\ProgramData\Bentley\OpenPlant CONNECT Edition\Configuration\WorkSpaces\OpenPlantExample\WorkSets\Metric\Standards\OpenPlant\Isometrics - Open Isometrics.cfg in notepad++
Path: C:\ProgramData\Bentley\OpenPlant CONNECT Edition\Configuration\WorkSpaces\OpenPlantExample\WorkSets\Metric\Standards\OpenPlant\Isometrics
- Add variable LOOKUP_MAP and give the required path in the highlighted part.
- Sync to ProjectWise and verify the result.