Sometimes user must do modeling by using Point cloud data or match lines as per site condition (As build) modeling, where pipe coordinates not proper or pipeline deviated from some angle. when generate isometric for such lines shows Rolling offset Dimension. If user want to avoid those dimensions, following steps needs to follow.
Expected Result:--Steps to Accomplish
Save the style.cfg file
Generate isometric to review the result.Some more cases:--The default IE_ANGLE_TOLERANCE is set to 0.01 degrees Example: The left pic show what is modeled, the right pic uses a setting of IE_ANGLE_TOLERANCE=4 The line is now shown vertical, the angle on the elbow however remains 87.3
See Also
Comments or corrections?Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!