How to add SPEC Criteria in Project Iso so as user can use Spec Criteria for Project Iso
User requirement to add Spec as default Break Criteria in the Project Iso.
1.Navigate to the OpenPlant folder of the specified Project where Spec need to be added in the given Isostyle.
C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant
2.Open OPIM.ini file and add Spec Criteria manually as shown below.
3.Once the above changes are made generate the Isometrics and verify that Spec Criteria is coming in Isometrics dropdown Window.
AutoPLANT - OpenPlant Isometrics Manager CONNECT Edition OpenPlant Isometrics Manager CONNECT - AutoPLANT See Also AutoPLANT Modeler CONNECT Edition Work remotely or connected with the market’s most productive and easy-to… Last edited over 4 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!