If project requirement needs to show some component properties values in long description section. Following illustrative steps will help to achieve desired result.
1. Navigate to the project Isometric Style path.
Ex: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\Isometrics\styles\IFC\config
2. Open report.def file in notepad. Add the following lines in Shop and Field section:
# COLUMN = 60: W : IE_DESCRIPT and COLUMN = 60: W : if (IE_TYPE="CT_RPAD", (SHORT_DESCRIPTION),IE_DESCRIPT)
Save and Close
Take note that “#” means the given row will not be read by the system.
3. Generate the isometric and review the result. Short description of component is populated under long description section.
OpenPlant Isometrics Manager CONNECT - AutoPLANT See Index: See Also Product TechNotes and FAQs OpenPlant Isometrics Manager [FAQ] External Links Check Videos Content - LEARN Server Comments or Corrections? Bentley's Product Advantage… Last edited 5 months ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!