10.10.01.39, 10.11.00.260
The Note Text added for the Note Component does not display correctly in the tooltip
1. Launch Class Editor
2. Open OpenPlant_3D schema
3. Supplement it with ModelingViews schema (see (+) How to Open Schema & Supplement it with desired Schema in Bentley Class Editor CONNECT Edition. - OpenPlant | AutoPLANT Wiki - OpenPlant | AutoPLANT - Bentley Communities)
4. Go to the Note Class
5. In the Properties tab, select the COMPONENT_NAME and Add/Remove Custom Attributes
6. Change the location for the Calculated ECProperty Specification from OpenPlant_3D_Supplemental_ModelingViews to OpenPlant_3D
7. Save the schemas
8. Launch OpenPlant Modeler and add a Note
If above problem still persists, then please create a Service Request and contact the Bentley Technical Support Group. Please include a list of all relevant details to get in depth analysis for a solution or workaround