Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Show Pipeline Continuation for Connected Pipeline in OpenPlant Isometrics Manager Connect Edition Using PlantSight
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • -OpenPlant Isometrics Manager CONNECT
          • [FAQ] - OpenPlant Isometrics Manager CONNECT Edition
          • Release Notes- OpenPlant Isometrics Manager CONNECT Edition
          • +OpenPlant Isometrics Manager CONNECT - OpenPlant
          • +OpenPlant Isometrics Manager CONNECT - AutoPLANT
          • How the North for isometrics can be change in OpenPlant Isometrics Manager CONNECT Edition.
          • How to add End type Information in Isometric BOM Cut list OPIM CE
          • How To Add Field components Under Shop Material In BOM OPIM CE
          • How to Add Plant Area in Isosheet Name.
          • How to change Dimension color in OPIM CE
          • How to convert units of Dimension & Size in Isometrics.
          • How To Create Custom Style in OpenPlant Isometrics Manager Connect Edition .
          • How to Create new Drawing Attribute Combining Multiple other Drawing Attributes and Map with New Text Node in OpenPlant Isometrics Manager
          • How to customization ISO sheet number (split sheet number / Total number of sheet) In OpenPlant Isometrics Manager
          • How to disable Dimension for Existing Component State
          • How To Display only Support List for Bill Of Material Report in OpenPlant Isometrics Manager
          • How to Generate Reports based on Size in OpenPlant Isometrics Manager Connect
          • How to get Co-ordinate Values in Meters in Iso Output via OPIM
          • How to Get Updated Revision in Isometrics Drawing Using DBQuery in OpenPlant Isometric Manager CONNECT Edition
          • How to Hide Branch Dimensions
          • How to modify/edit Dimension Text of extracted DWG from OPIM CE
          • How to place Text Node in OPIM CE
          • How to Remove Insulation/Tracing for desired components in Isometrics.
          • How To Resolve the error message " OPIM_SCHEMA_PATH points to an invalid location".
          • How To Set Reducer Size Annotation for Bill Of Material Report in OpenPlant Isometrics Manager
          • How To Set Reducer Size Annotation in BOM Report OPIM CE
          • How to Show 3 Port Information PIPE_LATERAL_TEE_REDUCING_ONE_RUN_AND_BRANCH in Isometric Drawing
          • How to Show Calculated Pipe Weight for Bill Of Material in OpenPlant Isometrics Manager
          • To Fix Bend Angle Precision value in OpenPlant Isometrics Manager
          • How to Show Pipe Support Coordinates in OpenPlant Isometrics Manager
          • How to Add Failure Class to Valve
          • How to Add New Attribute in PCF File in OpenPlant Modeler Connect Edition
          • How to Add Round Bubble instead of Rectangular around Tag
          • How to Assign FieldFit Weld Allowances or Other Weld Types for BOM & Cut List in OpenPlant Isometric Manager Connect Edition
          • How to Change Cursor Crosshair Color in OpenPlant Isometrics Manager CONNECT Edition
          • How to change Paper Size PDF Output
          • How to Convert Component's User Label from Decimal to Fraction in OpenPlant Isometrics Manager CONNECT Edition
          • How to Display Eccentric Reducer Offset Label in OpenPlant Isometrics Manager CONNECT Edition
          • How to Display Negative Coordinates Using Configuration Changes in OPIM
          • How to Fix Spool Label, Flipped Upside Down while moving in Isometric Modeler Connect Edition
          • How to Resolve Unable to place symbol: SWEBW_MT in OPIM CE
          • How to Show Pipeline Continuation for Connected Pipeline in OpenPlant Isometrics Manager Connect Edition Using PlantSight
          • How to Show Shop and Field Information for Welds in OpenPlant Isometrics Manager CONNECT Edition
          • To Display Multiple Content in a Rows as Label in OpenPlant Isometric Manager Connect Edition
          • To Display Multiple Content in the Rows as Label in OpenPlant Isometric Manager Connect Edition
          • To Display New Property in Description Field For BOM in OpenPlant Isometrics Manager Connect Edition
          • To Display UNIT Information for Support in BOM for OpenPlant Isometric Manager Connect Edition
          • To Modify the Spool ID Labeling in OpenPlant Isometric Manager Connect Edition
          • To Resolve Bolt Length Conversion Issue in OpenPlant Isometric Manager
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
        • To Clean Residual Files After Uninstalling OpenPlant
        • To Fix Dialog not Showing After Disconnecting Multiple Monitor Display
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!
    • Learning Content for OpenPlant

     
     Questions about this article, topic, or product? Click here. 

    How to Show Pipeline Continuation for Connected Pipeline in OpenPlant Isometrics Manager Connect Edition Using PlantSight


    Applies To 
    Product(s): OpenPlant Isometrics Manager CONNECT Edition
    Version(s):

    10.11.00.260

    Environment:  Windows 10 (64-bit)
    Area:  PlantSight & OpenPlant Isometrics Manager
    Subarea:  XXXX
    Original Author: Chanchal Mashalkar, Bentley Global Technical Support

    Background

    In many situations, the user requires access to the created isometric's pipeline continuation. The most recent version displays the information accurately, but the prior version displayed several errors while conducting an action. The steps to complete it are listed below.

     

    Note: The user workset needs to be linked to the PlantSight Project for this to work.

    Steps to Accomplish

    1. Launch OpenPlant Modeler in open new .dgn file.



    2. Place one pipeline of nominal size 3-inch using default pipe specification (Example) and joint one weldneck flange on one of the pipes ends as shown in the fig.



    3. Perform check-in to PlantSight.


    4. After check-in the OPM environment will get blank means, it has connected with PlantSight. After this Click on Explorer and go to that pipeline to Reference out. (Right click on that pipeline and choose option Reference out).



    5. Create a new pipeline with mating component such as flange and form the connection with bolt and gasket.



    6. Then Click on Clear reference as stated in image below.



    7. After clear reference click on check-in all and observed that all the model is getting blank.


    8. Now from Explorer Check-out both the pipeline as you did this the pipeline visible to you.





    9. Run the connectivity checker to see for any disconnection.



    10. The last step is to generate the isometric for both the pipeline and observed that there is a continuation of the pipeline.



      Select both the pipeline and select IFC as isometric style and generate isometric.



    11. To verify the result, generate the isometric observed that there isa continuation of the pipeline.





    Still a Problem?

    If above problem still persists, then please create a Service Request and contact the Bentley Global Technical Support group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.

    • Share
    • History
    • More
    • Cancel
    • Chanchal Mashalkar Created by Bentley Colleague Chanchal Mashalkar
    • When: Wed, Mar 29 2023 10:42 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies