Background

Define configuration variable OPM_PREFER_MEGALUG =1 to enable MegaLug joints.

The Series 2100 MEGAFLANGE Restrained Flange Adapter is a field-adaptable wedge style restrained flanging system. It has a restraint ring and a gasket ring which gives you the maximum amount of flexibility during and after installation.

A typical MEGAFLANGE Adapter is drawn in OpenPlant Modeler according to the following mapping of the properties in the Catalog\Spec mdb file. 
To place Mega lug flange using auto-fitting , follow these steps:

Steps to Accomplish

  1. Place a pipe of desired length.

  2. Select the Flange option from the Piping Galleries.
    In the Component Center, the list of available flanges appears.

  3. Select the Weldneck flange and continue to place it from the end of the pipe.
    The flange adapter gets placed automatically.