“How to Resolve the Eccentricity of the Pipe Adapter in Open Plant Modeler Connect Edition?”



Applies To 
Product(s):OpenPlant Modeler CONNECT Edition
Version(s):

10.09.02.11 & Above

Environment: Windows 10 (64-bit)
Area: Piping Network System
Subarea: Pipeline
Original Author:Chanchal Mashalkar, Bentley Global Technical Support

Background

While Launching OpenPlant Modeler and trying to place the male Pipe Adapter, it is observed that Eccentric graphic has been placed instead of Concentric one. This document will explain how to get rid of this issue.

Steps to Accomplish

  1. Launch Class Editor
  2. Open 3D modelling schema and supplemented with modelling and modelling views schema Workset.
  3. Go to Pipe Adaptor and do the necessary changes in the Creation Attribute as shown in the image below.(Eccentric Piping Reducer to Concentric Piping Reducer)


  4. Launch OPM again and place the Pipe Adapter and verify the result.
  5. Below is the image of showing the Concentric graphic for Pipe Adapter instead of eccentric one.

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.