How to Show Schedule and Rating Under Same Column in BOM in OpenPlant Isometrics Manager CONNECT Edi


 
 Applies To 
  
 Product(s):OpenPlant Isometrics Manager CONNECT Edition 
 Version(s):10.XX.XX.XXX
 Environment: Windows 10 (64-bit)
 Area: Settings/Attributes
 Subarea: -
 Original Author:Evander Cabalagan, Bentley Global Technical Support
  

Background

OpenPlant Modeler and AutoPLANT Modeler have schedule and rating for every piping component. Moreover, user has a requirement to group the schedule and rating in a single column either Shop or Field. Kindly follow the steps below to achieve the goal.

Steps to Accomplish

1. Launch OpenPlant Modeler and open a piping model. For example, pipe with weld neck flange.

2. Proceed and open report.def by selecting the appropriate workspace, workset and isometric style.

3. Enter the value COLUMN = 15: L : SCHEDULE + " " + RATING.
Note: Column width and alignment values can be changed.

4. Save and close report.def file.
5. Open isoseed.dgn in same folder location of report.def file.

6. Manually edit and add text in BOM header then click save settings.

7. Generate isometrics and verify the result.

          

See Also
communities.bentley.com/.../13393.settingsattributes-openplant-isometrics-manager

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!