How to add Value name for Valve in BOM



Applies To 
Product(s):OpenPlant Isometric Manager
Version(s):

CONNECT Edition 10.11.++

Environment: Windows 10/11 (64-bit)
Area: BOM.
Subarea: Values
Original Author:Nikitesh Kawana, Bentley Global Technical Support


Background

BOM should have valve name and not the description of Valve.

 Steps to Accomplish

  1. Start Bentley Class editor
  2. Open OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.08.ecschema.xml Schema
    1. Reference OpenPlant_IsoExtractor_Custom_Attributes.01.08.ecschema.xml Schema
  3. Search for Valve
  4. In Default Bill of Material label Dialogue box, IE_DESCRIPT attribute, change value to this.name


  5. Start OPM and generate ISO, and check for results