OpenPlant | AutoPLANT Wiki To Resolve Synchronization stops when Offpage Connector is deleted
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • -OpenPlant PID CONNECT
          • [FAQ] - OpenPlant PID CONNECT Edition
          • +What's New in OpenPlant PID CONNECT Edition
          • +Resolved issues in OpenPlant PID CONNECT Edition Releases
          • -Errors, Logs, Messages, Crashes in CONNECT - OpenPlant PID
            • How to fix PlantSight Synching Error "Some PlantSight instances could not be locked for Update, Synchronization stopped"
            • How to fix “Error -Unable to transform,property, GUID..” in PlantSight Connected Environment.
            • How to Modify Component Property values in OpenPlant PID
            • How to Resolve Synchronization Stopped Error during Syncing from PlantSight to Drawing after Adding New Associated Item and its Relationship in OpenPlant PID CE
            • How to Retrieve connected Pipeline Tag on inline Instruments
            • How to setup Pipeline Annotation on specific distance from Pipeline
            • To Fix Instrument Line Style Scale Issue raised in Imperial Workset in OpenPlant CE U9
            • To Fix Pipe Run Tag requires Relationship issue while Placing Pipeline in OpenPlant PID CONNECT Edition
            • To Fix the Gap on Placement of Custom Component on Pipeline in OpenPlant PID CONNECT Edition
            • To Resolve Crash when trying to open DGN from Microstation or PlantSpace in OPPID CE
            • To Resolve Synchronization stops when Offpage Connector is deleted
          • How to Add Actuator along with its Graphics to Existing Actuator List on Control Valve Placement in OpenPlant PID CONNECT Edition.
          • How to Add additional Panels into Existing Location List of Instrument Bubble Location during Control Valve Placement in OpenPlant PID CE
          • How to add the Reattach Instrument Bubble and Annotation option in the OpenPlant PID
          • How to Cascade Pipe Run Specification property in Valve's Property in OpenPlant PID CONNECT Edition
          • How to Cascade Operating Condition Property from PipeRun to Instrument in OpenPlant PID CE U8
          • How to Change Equipment Annotate TextStyle from Default Way
          • How to Change Origin Point from Existing One for Custom Component in OpenPlant PID CONNECT Edition
          • How to Change Pipe Run's Pipeline in OpenPlant PID CONNECT Edition
          • How To Change Text Style Attributes In OpenPlant PID For A Default Text Style
          • How to Change the Default Line Jumper in OpenPlant PID CONNECT Edition
          • How to Clear EC Properties for Components in OpenPlant PID CONNECT
          • How to Configure SQL Database to Enlist On Any Client Machine
          • How to Control Jumper Gap for Instrument & Process Lines in OpenPlant PID CONNECT Edition
          • How to Control Tag Properties when Placing Assemblies in OpenPlant PID CONNECT Edition Update 9
          • How to Create a Custom Instrument in OpenPlant PID CONNECT Edition.
          • How to Create a Spec Driven Custom Valve in OpenPlant PID CONNECT
          • How To Create Associated Property Using OpenPlant Project Administrator in OpenPlant PID Connect Edition
          • How to Create Custom Component in OpenPlant PID CONNECT Edition
          • +How to Create Custom Ribbon Group, Custom Tool Button & Gallery in OpenPlant PID CONNECT
          • How to Create Group of Components through Named Group in OpenPlant PID CONNECT Edition
          • How to Create Validation State for Component in OpenPlant PID CONNECT
          • How to Define Color for Flow Arrow in OpenPlant PID CONNECT Edition
          • How to Define Desired Text Justification for Pipeline Annotation in OpenPlant PID CONNECT Edition
          • How to Disable Working Offline Window during Launching of OPPID CE
          • How To Enable or Disable Rotation for OFF-PAGE CONNECTOR in OpenPlant PID Connect Edition.
          • How to Fetch Spec Records for Custom Component in OpenPlant PID CONNECT Edition
          • How to Format Default Number Property in OpenPlant PID CONNECT Edition
          • How to Import Pipeline list & its Properties from Excel Sheet in OpenPlant PID CONNECT
          • How to Include Pipe Line Number in OOTB Valve Reports through Reporting Designer in OPPID CE
          • How To Modify Default Value for Device Type Code to a Specific Component Class in OpenPlant PID Connect Edition
          • How to Modify/Add Validation State to Components in OpenPlant PID Connect
          • How to move the Equipment's Annotation along with it.
          • How to Place an Actuator on Normal Valve in OpenPlant PID CONNECT Edition
          • How To Place Text through Insert Function In OpenPlant P&ID Connect Edition
          • How to Populate Document Description on Valve Properties in OpenPlant PID
          • How to Reflect Pipeline Number during Placement of Spec Break in OPPID CE in OpenPlant PID CONNECT Edition.
          • How to Reflect Pipeline Number on Blind Flange's Properties in OpenPlant PID CONNECT Edition
          • How to Reflect Pipeline Number on Pipe Cap Properties in OpenPlant OpenPlant PID CONNECT Edition
          • How to Remove Elements from Graphics Group through Named Group in OpenPlant PID CONNECT Edition
          • How to Set Default Annotation of Pipe Run with Pipeline Tag in OpenPlant PID CONNECT Edition
          • How to Set Inline Component Symobology as that of Pipeline in OpenPlant PID CE U8
          • How to Set Show Flow Arrows to True in Default way in OpenPlant PID CONNECT Edition.
          • How to Set SteamTrap Tag Number in Default on Placement in OpenPlant PID CONNECT Edition
          • How to Show Imperial & Metric sizes in the Same Project in OpenPlant PID Connect Edition
          • How To Show Information from Pipeline to In-Run Components in OpenPlant PID Connect Edition.
          • How to Stop Pipe Runs getting converted to Major Pipelines after upgradation of project from OPPID V8i to CONNECT Edition.
          • How to Suppress Trailing Zeroes from Properties value in OPPIDCE
          • How to Use External Database Custom Attribute against Property in OpenPlant PID CONNECT Edition Update 9
          • Nozzle numbers are not resetting to 1 for each Equipment in OPPID CE
          • +OpenPlant PID Synchronization to iModelHub
          • To Fix Pressure Unit Interpretation displayed for Pressure Gauge Reflected as, “манометр” Instead of, “Избыточное” in Russian Version of OpenPlant PID CE.
          • To Resolve Gap Formation on Pipe and Instrument Lines in OPPID
          • How Change/Replace modeled valve in OpenPlant PID CE
          • How do Modify (Re-size, Scale) the Component Flow Arrow in OPPID CE
          • How to Add Bubble Location For Flow Meter in OpenPlant PID CONNECT Edition
          • How to add custom border in OpenPlant PID CONNECT Edition
          • How to add Open/Closed state display for Valves
          • How to Cascade Custom Property from Pipe Run to Control Valve as Default Value in OpenPlant PID
          • How to change PLANT_AREA in OPPID Connect without using PlantSight
          • How to change the component color template in OpenPlant PID CONNECT Edition
          • How to Configure OpenPlant PID CONNECT Edition to Use Workspace from Shared Location.
          • How to Create New Pipeline with specific line Style
          • How to customize the Valve Tag Number to start at another default value other than 0 in in OpenPlant PID Connect Edition
          • How to Extend cells for Parametric Instruments
          • How to Keep Control Valve Description Intact, while running Inrun Spec Validation
          • How to Place Control Valve With a Solenoid( Letter 's' ) With a Style
          • How to Pull Pipeline Annotation to Off-Page Connectors Annotation
          • How to reset Tag Browser Dialog size and location
          • How to Resize the Actuators of Control Valve Actuators in OpenPlant PID CE
          • How to set Tag Numbering options for Assembly Placement and Paste from Clipboard
          • How to set the OpenPlant PID to not delete the tag from Plantsight when deleted from dgn file.
          • How to Show Save Changes Window At The Time Of Closing OPPID Application
          • How to Spec Break component with more than one property.
          • Maintenance Key-ins in OpenPlant PID CONNECT Edition Update 9.1
          • +Common OPPID Customizations
          • How to Add New Category and Property in OPPID CE
          • How to Add Units of Measurement on Property in OpenPlant PID Connect
          • How to Cascade Size Property to Tie from Pipe Run in OPPID CE
          • How to Change the Default Line Jumper to Squiggly Line Jumper in OpenPlant PID CONNECT Edition
          • How To Change the Default Name of a Pipe Run in OPPID
          • How to Change Unit of Measurement Displayed for Specific Property in OPPID CE
          • How to changes Cell graphics in OpenPlant PID CE
          • How to Configure Drawing Reports in OPPID
          • How to Configure Page Connectors to Show Pipe Run Equipment in OPPID
          • How to configure safety critical properties for parametric instruments in OpenPlant PID
          • How to Create a Mark-up Using Issue Tool inside PlantSight and Review it in OPPID
          • How To Create Custom Air Release Valves
          • How to Create Custom Pipeline Break based on Service Change in OPPID
          • How to Create Iso unit WorkSet in OPPID
          • How To Create Region with and without Cutout Area around Texts
          • How to Create Workset with ISO Standard in OpenPlant PID Update 10
          • How to Customize Existing Valve Tag in OpenPlant PID Connect Edition
          • How to Display Notes of Offpage Connector OPPID CE
          • How to enable Line Jumper for Pipeline in OPPID CE U10
          • How to get list of connected components to page connector using Advanced Query in PlantSight
          • How to Hide PlantSight Sync Settings in OPPID
          • How to Include Multiple Properties in Bubble Annotation
          • How to Make a Valve Replaceable in OpenPlant PID CONNECT Edition
          • How to manage nozzle relationship with equipment in OpenPlant PID CONNECT Edition
          • How to manage Number property upon Paste from clipboard
          • How to manage WBS property upon Paste from clipboard
          • How to Modify Tie-In Symbol and the Text in it for OPPID
          • How To Open a ProjectWise Enabled Drawing
          • How to Organize the Priority of the Category of Class
          • How to place valve with open and closed states in OpenPlant PID CONNECT Edition
          • How To Process the WorkSet for Reuse
          • How to pull strainers from specs based on Pipe size in OpenPlant PID CONNECT Edition
          • How to Replace Multiple valves at once in OpenPlant PID CONNECT Edition
          • How to see commit changes into PlantSight from OpenPlant PID
          • How to set Properties Priority under Category.
          • How to Set the Component to Break Pipeline at the Connection Point of the Cell in OPPID
          • How to show Actuator Tag with Control Valve
          • How to Sync PID Drawings with PlantSight using Batch Processing
          • How to Tag Equipment with Different Nozzle Numbers and Sync it to PlantSight
          • How to toggle the Tag dialog display for individual components
          • How to upgrade existing iTwin project using OPPA CE U10
          • How to use Refresh option in Standard Preferences in PlantSight connected mode
          • How To Use the Fence Stretch Command in OPPID
          • Key-in & Configuration Variables for OpenPlant PID CONNECT Edition
          • To Extend cells for Parametric Instruments
          • To Place Nozzle Name Annotations
          • To Resolve Inline Flow Elements Listing issue in Differencing Dialog During Sync to PlantSight
          • To Resolve Page Connector Workflow to Sync Changes Made in Pipe Run are Carried Across Multiple Drawing with Same Pipe Run
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
        • To Clean Residual Files After Uninstalling OpenPlant
        • To Fix Dialog not Showing After Disconnecting Multiple Monitor Display
        • To Fix Error "A required privilege is not held by the client" When Generating External Reports
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!
    • Learning Content for OpenPlant

     
     Questions about this article, topic, or product? Click here. 

    To Resolve Synchronization stops when Offpage Connector is deleted

     

    Applies To 
    Product(s): OpenPlant PID CONNECT Edition
    Version(s):

    10.09.01.08

    Environment:  Windows 8.1/10 (64-bit)
    Area:  Synchronization to PlantSight
    Subarea: 
    Original Author: Fer Mykiel Gonzales,Bentley Technical Support Group

    Background

    When the Off-page Connector is deleted in the DGN, the sync drawing in PlantSight stops. The Message Center shows the following error message:

    Steps to Resolve

    1. Open PID.cfg from %Workset_Standards_Location%\OpenPlant\PID\

    2. Search for IMODEL_SYNC_DELETECOMPONENTS

    3. Change the variable value to either 0 or 1.

    4. Save PID.cfg

    5. Try syncing the DGN to PlantSight with the OPC deleted



    Still a Problem?

    If above problem still persists, then please create a Service Request and contact the Bentley Technical Support group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround

    • synchronization
    • PlantSight
    • OPPID
    • Update 9
    • OPPID CE U9
    • Sync Error
    • OPC
    • Off Page Connector
    • OffPage Connector
    • OpenPlant PID CONNECT Edition
    • Share
    • History
    • More
    • Cancel
    • Fer Mykiel Gonzales Created by Bentley Colleague Fer Mykiel Gonzales
    • When: Mon, Oct 16 2023 9:59 PM
    • Fer Mykiel Gonzales Last revision by Bentley Colleague Fer Mykiel Gonzales
    • When: Wed, Oct 18 2023 2:37 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies