To Resolve Bolts missing for Wafer Lug Butterfly Valve in OPM



Applies To 
Product(s):OpenPlant Modeler CONNECT Edition
Version(s):

10.11.00.260 and above

Environment: Windows 11 (64-bit)
Area: Customization
Subarea: Schemas
Original Author:Sameer Bagwan, Bentley Global Technical Support


Overview

This document shares the reason for missing bolts for Wafer Lug type Butterfly valve and also a way to resolve it.

Problem Description

  1. In OOTB workset place a Valve with WLUG end preparation and place two flanges on each side.
  2. Notice that bolts are not getting placed.
  3. This is because OOTB mCS150 spec doesn’t have BOLT and MACHINE BOLT in spec, instead it only have STUD BOLT as seen below.


Steps to Resolve

  1. Add new record entry for BOLT and MACHINE_BOLT as per the standard dimensions  in the spec for testing lets copy any existing record and rename its EC_CLASS_NAME as BOLT, MACHINE_BOLT.
    Also its description can be changed as per standard definitions.


  2. Verify the results in the OPM.

 

Also See: To Resolve OPM showing Two sets of Machine Bolts and One set of Bolts for a Single Wafer Type Butterfly Valve connection

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround