How to Fix “loadpiping.scr” Can’t Find the File in AutoPLANT Modeler CONNECT Edition


Applies To
Product(s):AutoPLANT Modeler CONNECT Edition
Version(s):10.XX.XX.XXX
Environment:Windows 10 (64-bit)
Area:Errors, Logs, Messages, Crashes
Subarea:-
Original Author: Evander Cabalagan, Bentley Global Technical Support

Background

This error message appears while opening the dwg file or the model. The AutoPLANT Modeler will not open completely even OK button is selected. This issue happens when AutoCAD is not launched during the installation of AutoPLANT Modeler.

 

Steps to Accomplish

  1. Close all applications related to AutoPLANT Modeler.
  2. Launch AutoCAD and run the option command.
  3. In Profiles tab, select AutoPLANT_Modeler and Set Current.
  4. In Files tab, add the missing AutoPLANT Modeler path.
  5. Select Apply and Save the file.
  6. Open AutoPLANT Modeler to verify the result.

Still a Problem?

If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

See Also

communities.bentley.com/.../common-installation-issues-with-autoplant

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!