To Remove PartID Prefix from Spectacle Blind in OpenPlant Isometric Manager Connect Edition


Applies To
Product(s):OpenPlant Isometric Manager
Version(s):CONNECT Edition (10.11.01.136)
Environment:Windows 10/11 (64 bit)
Area:Isometric Manager
Subarea: Iso Generation
Original Author: Chanchal Mashalkar, Bentley Global Technical Support

Problem Description

In OpenPlant Isometrics Manager, user wants to remove PartID prefix for spectacle blind. Currently in generated isometrics spectacle blinds shows prefix as shown below.



Here requirement is to remove prefix “F” & only to show number for spectacle blind.

Steps to Resolve

  1. Using Bentley Class Editor, open OpenPlant_3D.01.08. ecschema of your particular project.

  2. Supplement with OpenPlant_3D_Supplemental_Modeling.01.08. ecschema, OpenPlant_3D_Supplemental_ModelingViews.01.08. ecschema & OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.08. ecschema.



  3. Navigate to Spectacle Blind class, search Isometric Component custom attribute as shown below.






  4. Change Class Name from CT_FLANGE to CT_SPACER as shown below.
    Class Name = CT_SPACER



  5. Save all the changes & verify the results as shown below.

Still a Problem?

 If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.

Comments or Corrections?

Bentley's Global Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!