To Resolve Isometric Drawing Connection Label showing "0:" instead of "Cont. to:"


Applies To 
Product(s): OpenPlant Isometrics Manager CONNECT Edition
Version(s):10.11.01.136
Environment: Windows 11 (64-bit)
Area: Isometrics
Subarea: Labels
Original Author:Fer Mykiel Gonzales, Bentley Global Technical Support

Overview

For isometrics having continuation label, the label shows as "0:" which is inconsistent to what is set in the Style Configuration. By default, the connection label should display as "Cont. to:

Problem Description

The Continuation Label shows inconsistency with what is set in the Style Configuration. This is true when using Isometric Break Point or Manually assigning piping components to isos through Pipeline Manager.

Below steps is the workaround for this issue.  

Steps to Resolve

  1. Launch Class Editor

  2. Open OpenPlant_3D.01.08.ecschema.xml and supplement it with OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.08.ecschema.xml.
  3. Go to the ISO_SHEET Class
  4. In the Continuation Expression Custom Attribute, modify the Expression to be:

    "Cont. to:$"& this.ISO_DRAWING

  5. Save all schemas
  6. Launch OPM
  7. Open a DGN associated to the same workset the schema belongs to.
  8. Generate an isometric of a pipeline

  9. Open the Style Editor



  10. Remove the value in the Isometric Drawing Connection Label then Save.



  11. Close OPM and relaunch. Generate the isometric to see the Connection Label.

Note: There are instances that user may encounter the issue when generating the isometric:

 y

If so, kindly follow the steps mentioned in To Troubleshoot Error Message "Unable to cast object of type 'System.DBNull' to type''System.String'." Error. - OpenPlant | AutoPLANT Wiki - OpenPlant | AutoPLANT - Bentley Communities

See Also

To Troubleshoot Error Message "Unable to cast object of type 'System.DBNull' to type''System.String'." Error. - OpenPlant | AutoPLANT Wiki - OpenPlant | AutoPLANT - Bentley Communities

Still a Problem?

If above problem still persists, then please log a Case and contact the Bentley Global Technical Support group.  While logging a case, please include all relevant information to get in-depth analysis for a solution or workaround. 

 