How to Change Linestyle of Instline Electric Instrument Line for Sheet Model


Applies To 
Product(s):OpenPlant PID
Version(s):08.11.12.03 (SS10)
Environment: Windows 7/8.1/10 (64 bit)
Area: Customization
Subarea: 
Original Author:Fer Mykiel Gonzales, Bentley Product Advantage Group

Background

In the sheet model, the default linestyle is 0. It is desired for instline electric instrument line to follow either electric/3 linestyle. This is for representation purposes and allows the user to preview the PDF export inside the sheet model.

Steps to Accomplish

  1. Open the PIDProjectTemplates.dgnlib, which can be found in %Project_Dataset_Location%\dgnlibs\, in OPPID.
  2. Open the Level Manager, set Symbology to Override and look for the Electric Level



    Note: By default, the Instline Electric is associated to the Electric Level. Therefore, if the Instline Electric belongs to a different level, kindly modify to its respective level.


  3. Change the linestyle



  4.  Close the Level Manager and save the dgnlib.
  5. Launch OPPID
  6. Open the Default Model
  7. Open the Level Manager and update Library



    Check if the Override Symbology has been changed for the Electric Level:



  8. Open the Sheet Model with the referenced Default OPPID Model



  9. Open Reference and Detach the Default Model
  10. Attach Reference again
  11. Right-click the Referenced Model and open Presentation Dialog



  12. Use View Flags and toggle on the Level Overrides. Click Ok.



Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.