Applies To | |
Product(s): | OpenPlant Modeler |
Version(s): | CONNECT Edition Update 11 (10.xx.xx.xxx) |
Environment: | Windows 10/11 (64 bit) |
Area: | Settings |
Subarea: | - |
Original Author: | Joseph Gelacio, Bentley Global Technical Support Group |
OpenPlant Modeler now allow you to apply a SPEC_GROUP_FILTER attribute which lets you group specifications according to the Service selected. This allows you to limit the number of specs to choose from in the Specification list when defining a pipeline using a particular service.
Open the Class Editor (included with the OpenPlant Project Administrator install) and load the OpenPlant3D3D.01.04 schema as shown below:
For instance, in the Create Pipeline dialog below, with Water defined as the Service, note that the specification list is limited to A1-OPM and B1-OPM, which were defined in the Service.txt file above.
See Also
communities.bentley.com/.../errors-logs-messages-crashes-in-connect---openplant-isometrics-manager
Comments or Corrections?
Bentley's Global Technical Support group requests that you please confine any comments you have on this Wiki entry to Forum section? section. THANK YOU!
communities.bentley.com/.../autoplant-axsys-openplant-plantwise-forum