Error: Unable to Associate Fastener (ID=7) with Joint, minDist=3.17 in OpenPlant Isometrics Manager


Applies To
Product(s):OpenPlant Isometrics Manager
Version(s):CONNECT Edition Update 11 (10.XX.XX.XXX)
Environment:Windows 10 (64 bit)
Area:Settings/Attributes
Subarea: -
Original Author:Evander Cabalagan, Bentley Global Technical Support Group

Background

The bolt label in generated isometrics is missing due to the error message appearing in isometrics configuration box. 
     

Steps to Accomplish

  1. Open style.cfg in preferred isometric style by selecting the appropriate Workspace and Workset.
  2. Add the value IE_UTH_MaxDistanceFastenerToPort= 6.5.
  3. Save the changes in style.cfg.
  4. Generate the isometrics to verify the result.

See Also

 communities.bentley.com/.../errors-logs-messages-crashes-in-connect---openplant-isometrics-manager   

Comments or Corrections?

Bentley's Global Technical Support group requests that you please confine any comments you have on this Wiki entry to Forum section? section. THANK YOU!

 communities.bentley.com/.../autoplant-axsys-openplant-plantwise-forum