Applies To | |
Product(s): | OpenPlant Isometrics Manager |
Version(s): | CONNECT Edition Update 11 (10.XX.XX.XXX) |
Environment: | Windows 10 (64 bit) |
Area: | Settings/Attributes |
Subarea: | - |
Original Author: | Evander Cabalagan, Bentley Global Technical Support Group |
In OpenPlant Isometrics Manager, there is a situation where an error occurs when generating the isometrics. It says Error: Symbol not mapped in [PCF] section: REFERENCE. This article aims to fix the problem by adding relevant values in the pcf.ini file.
Add the values at the bottom area of the file.
; annotations
; For annotations the EC CLASS is used fro mapping
; For annotation added by OPIM a pseudo class is used
REFERENCE = END-CONNECTION # reference label to other sheet/equipment
See Also
communities.bentley.com/.../errors-logs-messages-crashes-in-connect---openplant-isometrics-manager
Comments or Corrections?
Bentley's Global Technical Support group requests that you please confine any comments you have on this Wiki entry to Forum section? section. THANK YOU!
communities.bentley.com/.../autoplant-axsys-openplant-plantwise-forum