Content Publishing
Content Publishing Wiki Title Block Attributes are not updating in the rendition of an AutoCAD DWG File
    • Sign in
    • Content Publishing - Wiki
    • -Bentley i-model Composition Server
      • +Administrator - Bentley i-model Composition Server
      • +i-model Generation - Bentley i-model Composition Server
      • -PDF - Bentley i-model Composition Server
        • A rendition is not created from an iCS for PDF adhoc job
        • Adhoc jobs submit but do not run
        • All documents in an iCS Job are getting processed even though the Job was Started > Incremental.
        • Attribute Data attached to a Block (Cell) in a DWG file on a Frozen Layer is displayed and printed
        • Bentley i-model Composition Server (iCS for PDF) – Getting Started
        • Changing the default iCS for PDF printer
        • Controlling PDF Paper Sizes in iCS
        • Copy Environment from Source Folder
        • Could not establish trust relationship for the SSl/TLS secure channel
        • Could not locate ProjectWise document
        • Creating a multi-page PDF
        • Creating PDF's from multiple sheet models using iCS
        • Description of design file applied to description of rendition
        • Environment variables set by rendition service for character substitution
        • Error Calling Rendition web service, Login failed for user XXXX ('Domain\iCS server name$' in most cases)
        • Error calling the rendition web service
        • Error calling the rendition web service - Login failed for user
        • Error calling the rendition web service when creating a rendition with PW Explorer
        • Error code 100
        • Error code 32768
        • Error creating rendition and "Display descriptions" enabled in ProjectWise
        • Error trying to create PDF Renditions when I run a job or from ProjectWise Explorer
        • Failed to create plot set
        • How to create a rendition from all sheets in an Excel document
        • How to grayscale Office document renditions using iCS for PDF and InterPlot Organizer
        • How to point ProjectWise users to the new iCS server
        • iCS for PDF Performance
        • iCS - Keeping windows/temp clean
        • iCS for PDF - InterPlot Organizer ProjectWise login failed
        • iCS for PDF adhoc jobs are not publishing renditions - OF Administrator Database connection error
        • iCS for PDF adhoc jobs submit but do not run
        • iCS for PDF Email Notification Date/Time Settings
        • iCS for PDF Pause/Resume Service and Jobs
        • iCS for PDF Predefined ProjectWise Users
        • iCS Job hangs when it contains a Microsoft Office document
        • iCS jobs will not start
        • Incorrect fonts in generated .pdf through iCS for PDF Server
        • Incremental Job Change Criteria
        • Independent Control of Document Name, File Name, and Description
        • Installation - Generic error
        • Invalid argument passed to dmsapi function or Failed to create plot set
        • Job definition cannot be edited
        • Method not allowed
        • Multi-Page PDF from Flat Set using iCS for PDF
        • Partial Folder Mirroring
        • PDF Renditions of Office documents are blank
        • Project output destination
        • ProjectWise Explorer improvements with iCS for PDF
        • Recursive Folder Input
        • Rendition does not update title block attribute if attribute or tags are placed in reference file
        • RenditionService.svc is too busy
        • The custom line style is wrong displayed in the PDF file
        • Title Block Attributes are not updating in the rendition of an AutoCAD DWG File
        • Unable to obtain web service credentials
        • Unauthorized Access Exception 80070005
        • Understanding the iCS for PDF “Output Destination Folder” rendition component Create Version/Overwrite options
        • Video: Using IPLOT settings file in iCS for PDF
        • What are the recommended settings for the ProjectWise Dynamic Composition Server printer driver?
    • +ProjectWise Dynamic Plot Service
    • +ProjectWise Dynamic Plot Sync
    • ProjectWise Explorer Client
    • +ProjectWise InterPlot Driver Pack
    • +ProjectWise InterPlot Mid-Volume Driver Pack
    • +ProjectWise InterPlot Organizer
    • +ProjectWise InterPlot Organizer Connect
    • +SELECTsupport TechNotes and FAQs

    You are currently reviewing an older revision of this page.

    • History View current version

    Title Block Attributes are not updating in the rendition of an AutoCAD DWG File

     Applies To

      Product(s): Bentley i-model Composition Server for PDF
      Version(s): V8i and CONNECT Edition
      Environment:  Windows Server 2008 R2, Windows Server 2012
      Area:  PDF
      Subarea: 
      Original Author: Dawn Gentry, Bentley Technical Support Group
       

    iCS for PDF V8i and CONNECT Edition will use MicroStation to process AutoCAD DWG files when creating the PDF rendition. If the ProjectWise title block attributes are not getting updated in the PDF rendition, there are two probable causes.

    When using iCS for PDF V8i and iCS for PDF CONNECT Edition, check the Attribute Exchange Rules in ProjectWise Administrator. Be sure to create the Attribute Class under MicroStation Title Blocks. Typically, you can copy the same section from the AutoCAD Title Blocks section which has already been defined.

    Next, make sure the attributes are set to update when the file is copied out – enable “Document is “Copied out” in the Properties of MicroStation Title Blocks.

    When using iCS for PDF CONNECT Edition to create renditions of AutoCAD DWG files, if MicroStation CONNECT Edition is being used as the print engine, the title block attributes will not update without a configuration change.

    AutoCAD block attributes are not displayed as MicroStation tags by default when displaying in MicroStation CONNECT Edition. When opening AutoCAD DWG files in MicroStation CONNECT Edition, you will see the title block text has a background:

    and if you analyze it, it is a text node, not a tag element:

    DWG files are configured to automatically convert to text nodes when displayed in MicroStation CONNECT Edition. To make them display as tags and therefore get updated in ProjectWise, you need to enable this feature. This configuration change needs to be made on the iCS server where MicroStation CONNECT Edition is installed for publishing PDF renditions.

    From ProjectWise Explorer on the iCS server, open the DWG in MicroStation CONNECT Edition. Next, close the file and check in, you will see the following dialog:

    Cancel this dialog, you will see the dialog below:

    Right click on a dwg file and select options:

    Check the option “Block Attributes as Tags”:

    This setting is saved to a file called DwgSettings.rsc. This file is typically stored in the user’s preferences folder (the user logged in when setting in DWG options). My file was located here:

    C:\Users\dawn.gentry\AppData\Local\Bentley\MicroStation\10.0.0_1\prefs\dwgdata

    I copied this file to a location that was more central to all users for user with iCS for PDF but you could put it anywhere:

    C:\ProgramData\Bentley\MicroStation\10.0.0_1\prefs\dwgdata

    The following change should be made to the worksets used on the PDF rendition jobs. When opening the DWG files in MicroStation CONNECT Edition, I used the default workset:

    C:\ProgramData\Bentley\CONNECT Edition\Configuration\WorkSpaces\NoWorkSpace\NoWorkSet.cfg.

    I modified this file as follows:

    MS_DWGSYSTEMDATA = C:/ProgramData/Bentley/MicroStation/10.0.0_1/prefs/dwgdata/

    Restart the ProjectWise Orchestration Framework service so the new changes are picked up. The PDF renditions created should now update the title blocks.

    Now when you open the DWG file in MicroStation CONNECT, you should be able to see the Title blocks updated and therefore, the PDF renditions will have the correct information as well.

     

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies