ProjectWise Publishing Wiki Publish i-models without reference files using Bentley Automation Service.
    • Sign in
    • ProjectWise Publishing Wiki
    • -Bentley i-model Composition Server
      • +Administrator - Bentley i-model Composition Server
      • -i-model Generation - Bentley i-model Composition Server
        • Alternative source location
        • Bentley Automation Service CONNECT Edition - Application Integration
        • Bentley Automation Service CONNECT Edition delivers a new convenient log file conversion tool
        • Bentley Automation Service SS5 - Application integration
        • Bentley Automation Service SS6 - Application Integration
        • Bentley Automation Services Overview (iCS for i-models)
        • Composite i-model
        • Destination and Naming Convention Profiles
        • i-model Publishing Engine Application and Managed Workspaces
        • i-model Transformer/Validation
        • iCS job will not start
        • Importing Transformation Scripts in Automation Service
        • PDF links - moblie i-model does not include linked files
        • Publish i-models without reference files using Bentley Automation Service.
        • RealDWG support
        • Supported data types from Bentley i-model Composer
        • Video: Creating Mobile .imodel automated jobs in Bentley Automation Service
        • Video: Creating Published i-model automated jobs in Bentley Automation Service
      • +PDF - Bentley i-model Composition Server
    • +ProjectWise Dynamic Plot Service
    • +ProjectWise Dynamic Plot Sync
    • ProjectWise Explorer Client
    • +ProjectWise InterPlot Driver Pack
    • +ProjectWise InterPlot Mid-Volume Driver Pack
    • +ProjectWise InterPlot Organizer
    • +ProjectWise InterPlot Organizer Connect
    • +SELECTsupport TechNotes and FAQs

     
     Questions about this article, topic, or product? Click here. 

    Publish i-models without reference files using Bentley Automation Service.

    In Job Builder > Options > Publish Settings, “Publish Displayed Attachments Only” can be used to publish reference files that are displayed only and exclude references that are not displayed. This feature is available by default and can be used if the publishing engine (i.e MicroStation) supports it.

     

    Bentley Automation Service CONNECT Edition 10.00.02.01 and later contains an undocumented feature that can be used as an option to exclude all reference files, including self-references (active file attached to itself).

    To enable this feature, set the following system environment variable on the BAS server.

    EnableRemoveAllReferences=1

      

    With the system variable set, “Remove all reference files” will be added to the Publish Settings dialog.

     

    Remove EnableRemoveAllReferences as a system environment variable to remove this option.

    Contact Bentley ProjectWise Support for any questions regarding these steps. 

    • Share
    • History
    • More
    • Cancel
    • Todd Combs Created by Bentley Colleague Todd Combs
    • When: Thu, Dec 28 2017 9:46 AM
    • Todd Combs Last revision by Bentley Colleague Todd Combs
    • When: Thu, Dec 28 2017 9:48 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies