Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
ProjectWise
  • Product Communities
ProjectWise
ProjectWise Publishing Wiki Error Message: The assembly [varies] is not trusted due to SubjectCertExpired
    • Sign In
    • ProjectWise Publishing Wiki
    • +Publishing Documentation
    • -ProjectWise i-model Composition Server for PDF
      • +Administrator - ProjectWise i-model Composition Server
      • -PDF - ProjectWise i-model Composition Server
        • "Network Path Not Found" when running i-model Composition Server job
        • A rendition is not created from an iCS for PDF adhoc job
        • Adding Custom Form (Page) Sizes to Dynamic Composition Server Printer
        • Adhoc jobs submit but do not run
        • All documents in an iCS Job are getting processed even though the Job was Started > Incremental.
        • Attribute Data attached to a Block (Cell) in a DWG file on a Frozen Layer is displayed and printed
        • Bentley i-model Composition Server (iCS for PDF) – Getting Started
        • Changing the default iCS for PDF printer
        • Controlling PDF Paper Sizes in iCS
        • Copy Environment from Source Folder
        • Could not establish trust relationship for the SSl/TLS secure channel
        • Could not locate ProjectWise document
        • Creating a multi-page PDF
        • Creating PDF's from multiple sheet models using iCS
        • Description of design file applied to description of rendition
        • Environment variables set by rendition service for character substitution
        • Error Calling Rendition web service, Login failed for user XXXX ('Domain\iCS server name$' in most cases)
        • Error calling the rendition web service
        • Error calling the rendition web service - Login failed for user
        • Error calling the rendition web service when creating a rendition with PW Explorer
        • Error code 100
        • Error code 32768
        • Error creating rendition and "Display descriptions" enabled in ProjectWise
        • Error Message: The assembly [varies] is not trusted due to SubjectCertExpired
        • Error trying to create PDF Renditions when I run a job or from ProjectWise Explorer
        • Failed to create plot set
        • Failed to created Rendition
        • Failing to create rendition in iCS
        • How to create a rendition from all sheets in an Excel document
        • How to grayscale Office document renditions using iCS for PDF and InterPlot Organizer
        • How to point ProjectWise users to the new iCS server
        • iCS for PDF Performance
        • iCS - Keeping windows/temp clean
        • iCS error: Unable to Locate Projectwise folder specified by ID
        • iCS for PDF - InterPlot Organizer ProjectWise login failed
        • iCS for PDF adhoc jobs are not publishing renditions - OF Administrator Database connection error
        • iCS for PDF adhoc jobs submit but do not run
        • iCS for PDF Email Notification Date/Time Settings
        • iCS for PDF Pause/Resume Service and Jobs
        • iCS for PDF Predefined ProjectWise Users
        • iCS Job hangs when it contains a Microsoft Office document
        • iCS jobs will not start
        • Incorrect fonts in generated .pdf through iCS for PDF Server
        • Incorrect sizes generated when creating iCS for PDF renditions
        • Incremental Job Change Criteria
        • Independent Control of Document Name, File Name, and Description
        • Installation - Generic error
        • Invalid argument passed to dmsapi function or Failed to create plot set
        • Job definition cannot be edited
        • Method not allowed
        • Multi-Page PDF from Flat Set using iCS for PDF
        • Partial Folder Mirroring
        • PDF Renditions of Office documents are blank
        • Project output destination
        • ProjectWise Explorer improvements with iCS for PDF
        • Recursive Folder Input
        • Rendition does not update title block attribute if attribute or tags are placed in reference file
        • Rendition Failed to Create a moniker from a given a string
        • RenditionService.svc is too busy
        • The custom line style is wrong displayed in the PDF file
        • The MicroStation IPARM engine did not complete successfully - Milepost code: 0
        • Title Block Attributes are not updating in the rendition of an AutoCAD DWG File
        • Unable to obtain web service credentials
        • Unauthorized Access Exception 80070005
        • Understanding the iCS for PDF “Output Destination Folder” rendition component Create Version/Overwrite options
        • Video: Using IPLOT settings file in iCS for PDF
        • What are the recommended settings for the ProjectWise Dynamic Composition Server printer driver?
      • +Distribution Services
    • +ProjectWise InterPlot
    • +ProjectWise InterPlot Organizer
    • +ProjectWise InterPlot Driver Pack
    • +ProjectWise InterPlot Mid-Volume Driver Pack
    • +Bentley Automation Services
    • +ProjectWise Explorer Client
    • +Publishing Legacy Products

     
     Questions about this article, topic, or product? Click here. 

    Error Message: The assembly [varies] is not trusted due to SubjectCertExpired

    Summary:

    You may encounter errors when using I-Model Composition Server (ICS) Administrator after June 10, 2021.

    Background:  As a part of a continuing program to improve the security and integrity of Bentley software and services, over the last several releases, the ICS product added several security validation checks on program modules (.DLL files) that are loaded into memory.  Some of these validation checks were more stringent than intended. As a result, some legitimate and safe DLLs included with the product began to be rejected after June 10, 2021.

    The following provides the solution based on the Version of ICS you are running.

    Problem:

    • iCS for PDF 10.0.3.299

    Resolution:

    No resolution required.  We do not know of any issues with this software version.


    Problem:

    • PW Admin 10.0.3.434
    • PW Administrator 10.0.3.434 is being used to administer an ICS for PDF server operated by Bentley managed services.
    • You see error messages in Orchestration Framework log file or OF Admin stating "The assembly [varies] is not trusted due to SubjectCertExpired".

     Resolution:

    • As an alternative, you can use PW Admin 10.0.3.299.
    • If the registry key HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Server exists on your computer, please add the following value:

    [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Server],

    "IgnoreCertExpiration"=dword:00000001

    •  If the registry key HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Administrator exists on your computer, please add the following value:

    [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Administrator]

    "IgnoreCertExpiration"=dword:00000001


    Problem:

    • You are using version of ICS for PDF 10.0.3.280 or older, and,
    • You see errors in the Orchestration Framework log file or OF Admin interface like the ones below. 
      • “File  c:\users\administrator\appdata\local\bentley\orchestrationframework\aerendsvc10; of\extension\x86\rendsvcpwrefmirror.dll' is not signed by Bentley” or,
      • “Certificate chain for 'c:\users\administrator\appdata\local\bentley\orchestrationframework\aerendsvc10; of\extension\x86\rendsvcpwrefmirror.dll' is not valid. The certificate may be self-signed.”
    • Or, you may see the message “service is not running" while in OF Admin.

     Resolution:

    • If the registry key HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Server exists on your computer, please add the following value:

     [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Server],

    "ValidateCertificateChains"=dword:00000000

    •  If the registry key HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Administrator exists on your computer, please add the following value:

     [HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Bentley\Orchestration Framework\Administrator]

    “ValidateCertificateChains"=dword:00000000

    • Share
    • History
    • More
    • Cancel
    • Dana Guthrie Created by Bentley Colleague Dana Guthrie
    • When: Fri, Jun 18 2021 9:11 AM
    • Dana Guthrie Last revision by Bentley Colleague Dana Guthrie
    • When: Fri, Jun 18 2021 9:12 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies