You are currently reviewing an older revision of this page.
Error creating renditions from PW Explorer: “Error calling the rendition web service. –The remote server returned an unexpected response: (405) Method Not Allowed. Mscorlib – The remote server retuned and error: (405) Method Not Allowed.”
Open Server Manager. Expand features. Verify that WCF Activation has been installed for both HTTP and non-HTTP. Only non-HTTP is required but the install will error if you don’t have HTTP WCF activation.